- 2074 Bhadra · 8 marks
Degree of treatment, industrial wastewater
Short answer
Using Streeter-Phelps with base-10 constants (K=0.1, R=0.4), the permissible mixture ultimate BOD is 30.93 mg/l. After mixing with river (5 m³/s), the effluent BOD5 must be reduced from 5000 mg/l to 4589 mg/l, requiring 8.2% BOD removal.
You are assigned by an industry as a Sanitary Engineer to recommend the degree of treatment required for their industrial waste water. The effluent from the treatment plant is to be discharged into a river with a minimum flow of 5000 lps, a dissolved oxygen content of 7.4 mg/l and BOD of zero. In order to thrive aquatic life, it is necessary to maintain a minimum DO content of 4 mg/l in the river. A sanitary survey reveals the characteristics of industrial waste water as follows: Discharge = 2*10⁶ l/day; BOD = 5000 mg/l; DO = 0. Recommend the degree of treatment required for the plant. Assume saturation DO of 9.2 mg/l in the river after mixing with wastewater. It is equal to DO content of river before mixing. Assume any other appropriate data if required.
Convert flows to m³/s: m³/s and m³/s. The river is at about 20°C, so I assume the standard constants /day and /day (base 10), . Saturation DO after mixing is 9.2 mg/l, and the minimum DO to be kept is 4 mg/l.
Step 1: Mixing and permissible deficit
Step 2: Permissible BOD of the mixture
With and (base 10), . The critical deficit is
and must not exceed 5.20 mg/l. Solving these two equations for by trial (with fixed) gives mg/l, with days (check: mg/l).
Step 3: Permissible BOD of the effluent
So the treated effluent can have mg/l.
Answer: the effluent BOD5 must be brought from 5000 mg/l down to about 4589.49 mg/l, i.e. about 8.2% treatment (BOD removal) is required. The required degree is small only because the river dilution is very large (5 m³/s against 0.023 m³/s of waste); if the river flow were lower, much higher treatment would be needed.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Degree of treatment, town with dairy and industries · Sanitary Engineering, chapter 6
- Degree of treatment, domestic + industrial · Sanitary Engineering, chapter 6
- Is treatment necessary? Industry near river · Sanitary Engineering, chapter 6
- Degree of treatment, city 1200 l/s · Sanitary Engineering, chapter 6
- River flow required for 1500 population · Sanitary Engineering, chapter 6
- Is treatment necessary? Town wastewater 300 l/s · Sanitary Engineering, chapter 6
- Municipal wastewater treatment plant · Environment and Pollution Control, chapter 4
- Pipe outlet minimum water level, 50 lps · Irrigation and Drainage Engineering, chapter 7
- Dissolved oxygen by titrimetric method · Water Supply Engineering, chapter 4
- Point and non-point sources; waste water treatment · Engineering Chemistry, chapter 3