Is treatment necessary? Town wastewater 300 l/s

Short answer

Streeter-Phelps analysis: mixed flow 5.8 m³/s, initial deficit 1.04 mg/L, ultimate BOD 34.04 mg/L, f=4, critical time 1.87 days, critical deficit 5.54 mg/L > allowable 4.5 mg/L, so treatment needed. Required effluent BOD₅ ≤ 362.8 mg/L, corresponding to 19.4% BOD removal efficiency.

The wastewater generated from a newly established town is proposed to dispose in the nearby river. The characteristics of raw wastewater and that of river are as follows: Wastewater discharge = 300 l/s; BOD5 of wastewater at 20°C = 450 mg/l; The sewage is in putrefied state; Minimum river discharge = 5.5 m³/s; BOD5 of river at 20°C = 0 mg/l; DO of river = 8.5 mg/l; Temperature in the river after mixing = 20°C; De-oxygenation constant = 0.1/day (base 10) at 20°C; Re-oxygenation constant = 0.4/day (base 10) at 20°C; Saturation DO at 20°C = 9.1 mg/l; Allowable minimum DO deficit at d/s of disposal = 4.5 mg/l. Is treatment necessary? If so, what will be the required degree of treatment?

The oxygen sag (Streeter-Phelps) analysis is applied to the mixture of river and wastewater. Constants are in base 10.

Step 1: Conditions after mixing

Qmix=0.3+5.5=5.8 m3/sDOmix=0.3(0)+5.5(8.5)5.8=8.06 mg/L(putrefied sewage: DO≈0)D0=9.1−8.06=1.04 mg/LBOD5mix=0.3(450)+5.5(0)5.8=23.28 mg/LL0=BOD51−10−0.1×5=23.280.6838=34.04 mg/L\begin{aligned} Q_{mix}&=0.3+5.5=5.8\ \text{m}^3/\text{s}\\ DO_{mix}&=\frac{0.3(0)+5.5(8.5)}{5.8}=8.06\ \text{mg/L}\quad(\text{putrefied sewage: DO}\approx0)\\ D_0&=9.1-8.06=1.04\ \text{mg/L}\\ BOD_5^{mix}&=\frac{0.3(450)+5.5(0)}{5.8}=23.28\ \text{mg/L}\\ L_0&=\frac{BOD_5}{1-10^{-0.1\times5}}=\frac{23.28}{0.6838}=34.04\ \text{mg/L} \end{aligned}

Step 2: Critical deficit without treatment

f=K2K1=0.40.1=4f=\frac{K_2}{K_1}=\frac{0.4}{0.1}=4 tc=1K2−K1log⁡10[f(1−(f−1)D0L0)]=10.3log⁡10[4(1−3×1.0434.04)]=1.87 dayst_c=\frac{1}{K_2-K_1}\log_{10}\left[f\left(1-\frac{(f-1)D_0}{L_0}\right)\right]=\frac{1}{0.3}\log_{10}\left[4\left(1-\frac{3\times1.04}{34.04}\right)\right]=1.87\ \text{days} Dc=L0f10−K1tc=34.044×10−0.1×1.87=5.54 mg/LD_c=\frac{L_0}{f}10^{-K_1t_c}=\frac{34.04}{4}\times10^{-0.1\times1.87}=5.54\ \text{mg/L}

Since Dc=5.54D_c=5.54 mg/L is greater than the allowable deficit of 4.5 mg/L, treatment is necessary.

Step 3: Required degree of treatment

Find the maximum L0L_0 for which Dc=4.5D_c=4.5 mg/L (with the same D0D_0, by trial using the same equations): L0=27.45L_0=27.45 mg/L. Then

BOD5mix=27.45×0.6838=18.77 mg/LBOD_5^{mix}=27.45\times0.6838=18.77\ \text{mg/L}

The effluent BOD₅ that can be allowed is:

BOD5eff=18.77×5.80.3=362.8 mg/LBOD_5^{eff}=18.77\times\frac{5.8}{0.3}=362.8\ \text{mg/L} Efficiency of treatment=450−362.8450×100=19.4%\text{Efficiency of treatment}=\frac{450-362.8}{450}\times100=19.4\%

Answer: Treatment is necessary; the plant must remove about 19.4% of the BOD (effluent BOD₅ not more than about 362.8 mg/L).

✓ Answer checked by Claude Opus 5.5 (high effort)

All Sanitary Engineering chapter 6 questions →