- 2075 Chaitra · 6 marks
Pelton turbine design (6867 kW, 350 m)
Short answer
Discharge is 2.50 m3/s; with d/D=1/12 the required jets are 3.22, so use 4 jets; adjusted jet diameter is about 0.099 m and wheel diameter is 1.32 m.
A Pelton turbine has to be designed for the following data: power developed = 6867 kW, net head = 350 m, overall efficiency = 80%, speed = 550 rpm, coefficient of velocity () = 0.98 and speed ratio () = 0.46. Ratio of jet dia to wheel dia . Find discharge, number of jets, diameter of jet and diameter of wheel.
Data
kW, m, , rpm, , , .
Discharge
Wheel diameter
m/s
m/s
Jet diameter and number of jets
From : m.
Discharge through one jet .
With 4 jets the jet diameter is adjusted to carry the full discharge:
so (within the usual range 10 to 20). Specific speed: .
Answer: m³/s; 4 jets; jet diameter m; wheel diameter m.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Pelton unit speed, discharge, power · Hydropower Engineering, chapter 7
- Pelton turbine design (312.5 m, 5 m³/s) · Hydropower Engineering, chapter 7
- Turbine setting; three single-jet Pelton wheels · Hydropower Engineering, chapter 7
- Pelton wheel 70 kW: flow rate and diameter · Hydropower Engineering, chapter 7
- Francis runner design (40 m head, 10 m³/s) · Hydropower Engineering, chapter 7
- Multi-jet Pelton wheel design (200 m, 4 m³/s) · Hydropower Engineering, chapter 7
- Design of Pelton wheel for given power and head · Fluid Machines, chapter 3
- Pelton turbine design (3.75 m³/s, 380 m) · Hydro Power, chapter 7
- Wind turbine power, tip speed ratio and energy · Energy Resources, chapter 4