Short answer
Power = 0.8×9.81×10×40 = 3139 kW. Inlet diameter 1.52 m, width 0.25 m, guide vane angle 29.5°, specific speed 167.1, outlet diameter 1.23 m. For three units powerhouse dimensions approx. 25.5 m × 13 m × 19 m.
A Francis turbine works under a head of 40 m and discharge Q = 10 m³/s. The speed of the runner is 300 rpm. At the inlet tip of the runner vane, the speed ratio is and flow ratio . If the overall efficiency and hydraulic efficiency of the turbine are 80% and 90% respectively, assume discharge at the outlet is radial and velocity of flow is constant. Determine: a) power developed in kW; b) diameter and width of runner at inlet; c) guide vane angle at inlet; d) specific speed of turbine; e) diameter of runner at outlet. Dimension suitably the powerhouse (length, breadth and height) with a sketch, if three such turbines were used in a power plant. Assume suitably any requirements for calculations.
Data
m, , rpm, , , , . Radial discharge at outlet: , and .
m/s.
a) Power developed
b) Inlet diameter and width
m/s
m/s
(vane thickness neglected)
c) Guide vane angle at inlet
From :
Runner vane angle at inlet: since , , so with the backward tangent. Measured from the direction of motion of the wheel, the vane angle is (an obtuse, backward-curved vane).
d) Specific speed
e) Outlet diameter
The flow velocity is constant, m/s, and the water leaves without whirl in the axial direction, so the outlet flow area is a full circle:
Powerhouse dimensions for three units (assumed thumb rules)
Each unit: 3.14 MW, m. Assume a vertical shaft and a spiral casing outer diameter of about m.
| Item | Rule used | Value |
|---|---|---|
| Unit bay (centre to centre) | 5.5 m | |
| Erection (service) bay | one unit bay + | 7 m |
| End clearance | 2 m | |
| Length | about 25.5 m | |
| Breadth | generator + valve/gallery + control side | about 13 m |
| Draft tube depth | 3.8 m | |
| Distributor to generator floor | 4.5 m | |
| Generator floor to crane rail | generator height + lifting clearance | 8.5 m |
| Height (floor to roof truss) | 3.8 + 4.5 + 8.5 + 2 (roof) | about 19 m |
PLAN (3 units + erection bay) Section
+--------+--------+--------+-----+ roof
| unit 1 | unit 2 | unit 3 | EB | ========== crane rail
| (G) | (G) | (G) | | | G | generator floor
+--------+--------+--------+-----+ | TURB| turbine floor
25.5 m x 13 m \DT / draft tube
Answer: kW; m, m; ; ; m; powerhouse about 25.5 m x 13 m x 19 m.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Francis design (90 m, 40 m³/s, 86%) · Hydropower Engineering, chapter 7
- Francis overall efficiency with draft tube · Hydropower Engineering, chapter 7
- Francis design (90 m, 60 m³/s, 94%) · Hydropower Engineering, chapter 7
- Number of Francis/Kaplan units (300 m³/s, 30 m) · Hydropower Engineering, chapter 7
- Number and runner diameter of turbines (20 m head) · Hydropower Engineering, chapter 7
- Pelton unit speed, discharge, power · Hydropower Engineering, chapter 7
- Wind turbine power, tip speed ratio and energy · Energy Resources, chapter 4
- Francis turbine velocity triangles and power · Fluid Machines, chapter 3
- Design: 300 m head plant, GCB rating · Power Plant Design, chapter 4 · asked 11×
- Kaplan turbine discharge and blade angles · Fluid Machines, chapter 3