Number and runner diameter of turbines (20 m head)

Short answer

Total power is 3836 kW; specific speed gives 3274 kW per turbine, so use 2 turbines; runner diameter is about 1.69 m.

Determine the number of turbines and diameter of runner for a power plant having 23 cumecs inflow, 20 m head, turbine efficiency 85% and speed 170 rpm, specific speed 230 rpm and speed ratio 0.76.

Given

Q=23 m3/sQ = 23\ \text{m}^3/\text{s}, H=20H = 20 m, η=0.85\eta = 0.85, N=170N = 170 rpm, Ns=230N_s = 230, Ku=0.76K_u = 0.76.

Total power available

Ptotal=ηγQH=0.85×9.81×23×20=3836 kWP_{total} = \eta\gamma Q H = 0.85 \times 9.81 \times 23 \times 20 = 3836\ \text{kW}

Power per turbine from specific speed

Ns=NPH5/4  ⇒  P=(NsH5/4N)2=(230×201.25170)2=3274 kWN_s = \frac{N\sqrt{P}}{H^{5/4}} \;\Rightarrow\; P = \left(\frac{N_s H^{5/4}}{N}\right)^2 = \left(\frac{230 \times 20^{1.25}}{170}\right)^2 = 3274\ \text{kW}

Number of turbines

n=38363274=1.17⇒2 turbinesn = \frac{3836}{3274} = 1.17 \Rightarrow 2\ \text{turbines}

(One turbine of 3274 kW cannot carry the whole 3836 kW, so the next whole number is used. Each then develops 3836/2=19183836/2 = 1918 kW and takes Q=11.5 m3/sQ = 11.5\ \text{m}^3/\text{s}.)

Runner diameter

u=Ku2gH=0.762×9.81×20=15.05 m/su = K_u\sqrt{2gH} = 0.76\sqrt{2 \times 9.81 \times 20} = 15.05\ \text{m/s} D=60uπN=60×15.05π×170=1.69 mD = \frac{60u}{\pi N} = \frac{60 \times 15.05}{\pi \times 170} = 1.69\ \text{m}

Answer: 2 turbines; runner diameter ≈1.69\approx 1.69 m.