- 2072 Asoj · 8 marks
Head, specific speed and part load in turbine choice
Short answer
Head sets turbine type: Pelton high (above ~300 m), Francis medium (30–300 m), Kaplan low (2–40 m). Specific speed combines N, P, H and fixes runner shape; choose highest synchronous speed satisfying cavitation and runaway limits. Part-load: Pelton/Kaplan have flat efficiency; Francis peaks at 80–90% and is poor below 40–50%, so use multiple units.
Discuss the effect of the following factors in selecting of a turbine for a hydroelectric plant? (i) head (ii) speed and specific speed (iii) part load operation.
Turbine selection depends mainly on head, speed/specific speed and the expected part-load operation.
(i) Head
Head is the first and most important factor because it decides the velocity of water.
| Head range | Suitable turbine |
|---|---|
| High (above ~300 m, up to 1300 m) | Pelton (impulse) |
| Medium (30–300 m) | Francis (reaction) |
| Low (2–40 m) | Kaplan / propeller |
| Small plants, 3–250 m | Crossflow, Turgo |
- High head gives high jet velocity; an impulse turbine with small flow suits it.
- Low head needs large flow to give the same power, so a large flow-area axial runner (Kaplan) is used.
- Head variation also matters: Kaplan copes with varying head better than propeller.
(ii) Speed and specific speed
- Specific speed joins head, power and speed into one value that fixes the runner shape: Pelton 10–35, Francis 60–300, Kaplan 300–1000.
- A higher running speed gives a smaller, cheaper generator (fewer poles, ), so designers prefer the highest speed that is safe.
- But higher means a higher Thoma cavitation coefficient, so the runner must be set lower (more excavation), and the runaway speed is higher.
- Therefore the speed is chosen as the highest synchronous speed for which cavitation and runaway limits are satisfied.
(iii) Part-load operation
ROR plants often run at part load in the dry season, so the shape of the efficiency curve matters.
eff
| ____________ Pelton/Kaplan (flat)
| / ___
| / / \__ Francis (peaked)
|/ / \__ Propeller (sharp)
+--------------------> % load
0 25 50 75 100
- Pelton: efficiency stays high from about 20% to 100% load (flow controlled by needle; multiple jets can be shut).
- Kaplan: adjustable runner blades and guide vanes keep high efficiency over a wide range.
- Francis: best efficiency near 80–90% of rated load; falls quickly below about 40–50%, with vibration and cavitation.
- Propeller (fixed blade): very poor at part load.
If part-load running is expected, choose Pelton/Kaplan, or use several smaller Francis units so each runs near full load.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Specific speed of a turbine · Power Plant Design, chapter 3 · asked 2×
- Design: 300 m head plant, GCB rating · Power Plant Design, chapter 4 · asked 11×
- Design: 230 m head plant, 55 km line · Power Plant Design, chapter 4 · asked 12×
- Design: 310 m head plant, HV breaker · Power Plant Design, chapter 4 · asked 3×
- Design: 330 m head plant, 132 kV · Power Plant Design, chapter 4 · asked 12×
- Design: 120 m head plant, 33 kV · Power Plant Design, chapter 4 · asked 3×
- Model testing and specific speed of turbine · Fluid Machines, chapter 3
- Specific speed of a turbine · Fluid Machines, chapter 3
- Types of hydropower plants by head, turbine, load · Hydropower Engineering, chapter 2
- Choice of specific loadings in DC machine · Electric Machine Design, chapter 5 · asked 2×