- Asked 6/23
- 2081 Baishakh · 8 marks
- 2079 Bhadra · 8 marks
- 2078 Bhadra · 8 marks
- 2076 Asoj · 8 marks
- 2072 Chaitra · 8 marks
- 2071 Chaitra · 8 marks
Single-phase AC voltage controller with R load
Short answer
Two anti-parallel thyristors (T1 positive half, T2 negative half) are fired at angle α. Output is zero until α then equals supply until π, where current naturally extinguishes. The rms output voltage is V_o = V_s √[(1/π)(π - α + sin2α/2)].
With the help of suitable circuit diagram and waveforms, explain the operation of single phase AC voltage controller with resistive load. Derive the expression for rms value of output voltage as a function of firing angle.
A single-phase AC voltage controller changes the rms voltage applied to a load by delaying the firing of two anti-parallel thyristors (or a TRIAC) by an angle in each half cycle (phase control). The output frequency is the same as the input frequency.
Circuit
T1 --->|---
+---| |----+
| ---|<--- | |
| T2 |
( ~ ) vs = Vm sin wt R vo
| |
+-------------------+
T1 handles the positive half cycle and T2 the negative half cycle.
Operation
- : T1 is forward biased but not fired; no current; .
- : T1 is fired; it conducts and .
- : supply and load current fall to zero together (resistive load), so T1 turns off naturally (line commutation).
- : T2 is forward biased but not yet fired; .
- : T2 is fired; (negative) until .
The current has the same shape as the voltage: .
Waveforms
vs _ _
/ \ /
---/-----\---------/----
\ /
\_/
vo .
| \
-------|--\--------.------
0 a pi | / 2pi
| /
|/
pi+a
gates: T1 at a, T2 at pi+a
The output is an AC waveform with chopped beginnings of each half cycle.
RMS output voltage
With and by symmetry of the two halves:
Since :
- : (full voltage).
- : .
So the rms output is controlled smoothly from to 0 as goes from 0 to . The input power factor is , which falls as increases.
Applications: lamp dimmers, heater control, speed control of fans and small induction motors, soft starters.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- AC voltage controller rms at α = 90° · Power Electronics, chapter 6 · asked 2×
- AC voltage controller RL load extinction angle · Power Electronics, chapter 6
- AC voltage controller rms and ELC use · Power Electronics, chapter 6
- AC voltage controller RL load at α = 90° · Power Electronics, chapter 6
- AC voltage controller with R and RL loads · Power Electronics, chapter 6
- AC voltage controller, R = 10 Ω, α = 45° · Power Electronics, chapter 6 · asked 2×
- 3-phase half controlled bridge: no-load speed, firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×
- 3-phase thyristor bridge: no-load speed and firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×