Double-stub for Γ = 0.64∠58°
Short answer
Normalize the load to zL=0.807+j1.484, yL=0.283−j0.520; use short stubs, first at the load, spacing 0.375λ. Solution A gives stub lengths l1=0.1121λ and l2=0.0447λ. The matched network has S11=S22=0, |S21|=1; tuner S-parameters are S11=0.640∠149.7°, S21=S12=0.768∠−44.1°, S22=0.640∠−58°.
Design a double-stub impedance matching network for a load of Γ = 0.64∠58° connected to a 100 [?] Ohm transmission line. Prepare the S-Matrix of its matched network.
Given: ΓL = 0.64∠58°, Z0 = 100 Ω (taking the unclear value as 100 Ω). Assumptions: short-circuited stubs, the first stub at the load, spacing 3λ/8.
Load impedance
zL = (1 + Γ)/(1 − Γ) = 0.807 + j1.484
ZL = 80.73 + j148.43 Ω
Step 1: Normalise and convert to admittance
zL = 0.807 + j1.484
yL = 1/zL = 0.283 − j0.520
ΓL = 0.640∠58.0°, VSWR = 4.556
On the chart, zL is at 0.1694λ WTG and yL is diametrically opposite, at 0.4194λ WTG.
Step 2: First stub at the load
The first stub is placed at the load, so y1 = yL = 0.283 − j0.520.
Step 3: Forbidden-region check and rotated g = 1 circle
βd = 360° × 0.375 = 135°
g must be ≤ 1/sin²βd = 2.000
g1 = 0.2828 → matchable
Rotate the g = 1 circle by 0.375λ (270° on the chart) toward the load. The point just after stub 1 must lie on this rotated circle, so move from y1 along the constant g = 0.283 circle until it meets the rotated circle.
Step 4: Susceptance of stub 1
Analytically (Pozar), with t = tan βd:
t = tan 135° = −1.0000
b1 = −B + [1 ± √((1+t²)g − g²t²)]/t
(1+t²)g − g²t² = 0.4856, √ = 0.6968
Sol A: b1 = −1.1769
Sol B: b1 = +0.2167
Step 5: Move 0.375λ to stub 2 and find b2
Sol A: y after stub 1 = 0.283 − j1.697
(0.3333λ) → after 0.375λ: y2 = 1.000 + j3.464
b2 = −3.4643
Sol B: y after stub 1 = 0.283 − j0.303
(0.4497λ) → after 0.375λ: y2 = 1.000 − j1.464
b2 = +1.4643
Both y2 values lie on the g = 1 circle, as required.
Step 6: Stub lengths
- For a short-circuited stub: y = −j cot βl, so l = (1/2π)·cot⁻¹(−b); measure from the short-circuit point (y = ∞, right end of the chart) toward the generator.
Sol A short: l1 = 0.1121λ, l2 = 0.0447λ
Sol B short: l1 = 0.2840λ, l2 = 0.4046λ
| Quantity | Solution A | Solution B |
|---|---|---|
| Stub 1 from load | at load | at load |
| Stub spacing | 0.375λ | 0.375λ |
| b1, b2 | -1.177, -3.464 | 0.217, 1.464 |
| Short l1, l2 | 0.1121λ, 0.0447λ | 0.2840λ, 0.4046λ |
Answer (design): solution A, with l1 = 0.1121λ, l2 = 0.0447λ, and spacing 0.375λ.
Z0=100Ω 3λ/8
o------+---------------+--------[ZL]
| |
stub 2 stub 1
l2=0.0447λ l1=0.1121λ
SC SC
S-matrix of the matched network
Treat the tuner (stub 2, line 0.375λ, stub 1) as a two-port with both ports referenced to Z0. Port 1 faces the generator, and port 2 faces the load. The S-parameters come from the cascaded normalised ABCD matrix [1 0; jb2 1]·[cos βd j sin βd; j sin βd cos βd]·[1 0; jb1 1], with S11 = (A + B − C − D)/Δ, S21 = 2/Δ, S22 = (−A + B − C + D)/Δ, Δ = A + B + C + D.
Before matching:
S11 = ΓL = 0.640∠58.0°, VSWR = 4.56
Tuner, solution A:
S11 = 0.640∠149.7° S12 = 0.768∠-44.1°
S21 = 0.768∠-44.1° S22 = 0.640∠-58.0°
S12 = S21 (reciprocal), |S11|²+|S21|² = 1 (lossless)
S22 = ΓL* (conjugate match)
After matching (tuner + load):
Γin = S11 + S12S21ΓL/(1 − S22ΓL) = 0, VSWR = 1
Referred to the load (port 2 normalised to ZL), the perfectly matched network is S = [0 e^(−jφ); e^(−jφ) 0]. S11 = S22 = 0, and |S21| = 1, so all power reaches the load.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Double-stub matching 110+j110 Ω on 100 Ω line · RF and Microwave Engineering, chapter 2 · asked 2×
- Matching techniques and double-stub S-matrix · RF and Microwave Engineering, chapter 2
- Double-stub for inductive antenna load on 78 Ω line · RF and Microwave Engineering, chapter 2
- Double-stub microstrip network and its S-matrix · RF and Microwave Engineering, chapter 2
- Double stub advantages and matching steps · RF and Microwave Engineering, chapter 2
- Double-stub with assumed load on 50 Ω line · RF and Microwave Engineering, chapter 2
- Impedance matching techniques · Electromagnetism, chapter 5 · asked 3×
- Impedance diagram, 100 MVA 132 kV base, with load · Power System Analysis I, chapter 3
- Derive input impedance of transmission line · Electromagnetism, chapter 5
- Sequence impedance matrix of star load · Power System Analysis II, chapter 4 · asked 2×