Isolated PV sizing: lamps, fan and TV

Short answer

Daily load is 500 Wh. Adding inverter, wiring and battery losses gives required PV energy of 702 Wh/day; with 5 peak sun hours and 0.9 derating, panel size is about 156 Wp, so choose 160 Wp. Battery capacity is 292 Ah, choose 12 V, 300 Ah; inverter about 194 W, choose 250 VA.

A house is using in average the following electrical appliances:

  • Two 10 W lamp for 4 hours per day
  • One 60 W fan for 2 hours per day
  • One 75 W television used for 4 hours per day

The system has to be powered by isolated PV System with 12 V battery. Determine Size of the PV Panel, Inverter and Battery. (Consider wiring losses 20%, assume inverter efficiency 95% & for battery: efficiency is 90%, depth of discharge factor 0.6 and days of autonomy as 3. Make your smart assumption if further required)

An isolated PV system is sized by first finding the daily energy demand, then adding the losses to get the PV array rating, the battery capacity for the required autonomy, and an inverter that can carry the connected load.

Assumptions: all loads are AC (through inverter); wiring losses are taken as 20% extra energy; peak sun hours in Nepal = 5 h/day; panel derating (temperature, dust) = 0.9.

1. Daily load energy

LoadNo.Wh/dayWh/day
Lamp210480
Fan1602120
TV1754300
Total155500

2. Energy to be supplied by the battery (DC side)

Einv,in=5000.95=526.3 WhEDC=1.2×526.3=631.6 Wh/day\begin{aligned} E_{inv,in} &= \frac{500}{0.95} = 526.3\ \text{Wh} \\ E_{DC} &= 1.2 \times 526.3 = 631.6\ \text{Wh/day} \end{aligned}

3. Battery size

C=EDC×days of autonomyDoD×ηb×V=631.6×30.6×0.9×12=292.4 Ah\begin{aligned} C &= \frac{E_{DC} \times \text{days of autonomy}}{DoD \times \eta_{b} \times V} \\ &= \frac{631.6 \times 3}{0.6 \times 0.9 \times 12} = 292.4\ \text{Ah} \end{aligned}

Select 12 V, 300 Ah (e.g. two 12 V, 150 Ah batteries in parallel).

4. PV panel size

Energy the array must give (battery efficiency 90%):

EPV=631.60.9=701.8 Wh/dayPPV=701.85×0.9=155.9 Wp\begin{aligned} E_{PV} &= \frac{631.6}{0.9} = 701.8\ \text{Wh/day} \\ P_{PV} &= \frac{701.8}{5 \times 0.9} = 155.9\ \text{W}_p \end{aligned}

Select 160 Wp (two 80 Wp, 12 V panels in parallel).

5. Inverter size

Connected load = 155 W. With a 25% margin for surge (fan motor, TV) and future load:

Pinv=1.25×155=193.75 WP_{inv} = 1.25 \times 155 = 193.75\ \text{W}

Select 12 V DC / 230 V AC, 250 VA pure sine wave inverter.

6. Charge controller (extra)

I=1.25×160/12=16.7I = 1.25 \times 160/12 = 16.7 A, so a 12 V, 20 A charge controller.

Answer: PV array ≈ 156 Wp → 160 Wp; battery ≈ 292 Ah → 12 V, 300 Ah; inverter ≈ 194 W → 250 VA.