New kVA rating with fan cooling (400 kVA)
Short answer
From heat run 24°C (1h) and 34°C (2h): τ=1.14h (68.5min), θm=41.14°C. Max eff at 80% → Pi=0.64Pc, losses 1.64Pc. Improved cooling by 15%: same rise → losses ratio 1.15×1.64 → x=1.1162, rating 446.5kVA; 50°C rise → 1.15×50/41.14×1.64 → x=1.2853, rating 514.1kVA. Final rise 41.1°C; ratings 446kVA and 514kVA.
A 400 kVA transformer has its maximum efficiency at 80% of full load. During a short full load heat run, the temperature rise after one hour and two hours is observed to be 24°C and 34°C respectively. Find the thermal time constant and final steady temperature rise of the transformer. If, by use of a fan, the cooling is improved so that the rate of heat dissipation per unit area per degree rise in temperature is increased by 15%, find the new kVA rating possible (i) For the same final temperature rise as before (ii) If allowable temperature rise is taken as 50°C
Given
- Rating = 400 kVA; maximum efficiency at 80 % of full load
- Heat run at full load: °C after 1 h, °C after 2 h
- Fan cooling raises heat dissipation per unit area per °C () by 15 %
Step 1: time constant and final temperature rise
With , and :
Step 2: losses in terms of full-load copper loss
At maximum efficiency, copper loss = iron loss:
The final rise is , so the losses allowed . At a new load of times full load, the losses are (iron loss is constant).
(i) Same final temperature rise ( °C)
Losses allowed rise by 15 %:
(ii) Allowable temperature rise 50 °C
Losses allowed are now in the ratio :
Answer: time constant ≈ 1.14 h (68.5 min); final rise ≈ 41.1 °C; new rating (i) ≈ 446 kVA, (ii) ≈ 514 kVA.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- New kVA rating with fan cooling (350 kVA) · Electric Machine Design, chapter 2 · asked 2×
- New kVA rating with fan cooling (150 kVA) · Electric Machine Design, chapter 2
- Heating constant and 1-hour rating (400 kVA) · Electric Machine Design, chapter 2 · asked 2×
- Full-load heat run and 50% overload time · Electric Machine Design, chapter 2
- Heating constant and 1-hour rating (40 kVA) · Electric Machine Design, chapter 2 · asked 2×
- Machine temperature after one hour of heating · Electric Machine Design, chapter 2
- Temperature rise and tubes for 500 kVA transformer · Electric Machine Design, chapter 3 · asked 2×
- 500 kVA transformer efficiency, full and half load · Electrical Machines, chapter 2
- 500 kVA transformer efficiency full/half load · Electrical Machine, chapter 2
- Full-load efficiency of 500 kVA transformer · Electrical Machines I, chapter 2
- Full-load and half-load efficiency of 100 kVA transformer · Electrical Machines I, chapter 2