- 2073 Bhadra · 8 marks
Full-load and half-load efficiency of 100 kVA transformer
Short answer
Use efficiency = output/(output + iron loss + x^2 copper loss). At full load unity pf output is 100 kW, losses 2160 W, efficiency 97.89%. At half load 0.8 pf output is 40 kW, losses 1260 W, efficiency 96.95%.
A transformer is rated at 100 kVA. At full load its copper loss is 1200 W and its iron loss is 960 W. Calculate: i) Efficiency at full load, unity power factor ii) Efficiency at half load, 0.8 power factor
, with kVA, W (constant), W.
(i) Full load, unity pf ()
(ii) Half load, 0.8 pf ()
| Case | Output | Iron loss | Cu loss | Efficiency |
|---|---|---|---|---|
| FL, upf | 100 kW | 960 W | 1200 W | 97.89% |
| ½ FL, 0.8 pf | 40 kW | 960 W | 300 W | 96.95% |
Answer: (i) 97.89%, (ii) 96.95%.
Note: maximum efficiency occurs at , i.e. at about 89.4% of full load, where copper loss equals 960 W.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Full-load efficiency of 500 kVA transformer · Electrical Machines I, chapter 2
- Efficiency of 25 kVA transformer at half load and overload · Electrical Machines I, chapter 2
- Iron loss and maximum efficiency of 20 kVA 220/2200 V transformer · Electrical Machines I, chapter 2 · asked 2×
- Iron loss and maximum efficiency of 20 kVA 250/2500 V transformer · Electrical Machines I, chapter 2 · asked 2×
- Regulation and zero-regulation power factor of 100 kVA transformer · Electrical Machines I, chapter 2
- Half-load efficiency of 200 kVA transformer · Electrical Machines I, chapter 2
- 100 kVA transformer efficiency at full and half load · Electrical Machines, chapter 2
- 500 kVA transformer efficiency full/half load · Electrical Machine, chapter 2
- 500 kVA transformer efficiency, full and half load · Electrical Machines, chapter 2
- 20 kVA transformer iron loss, efficiency · Electrical Machine, chapter 2