Iron loss and maximum efficiency of 20 kVA 220/2200 V transformer

Short answer

Iron loss is V1^2/R0=96.8 W. Maximum efficiency occurs when copper loss equals iron loss, giving primary current 49.19 A, about 54% of full load, and maximum efficiency 98.24% at unity pf.

A 20 kVA, 220V/2200V, 50 Hz single phase transformer has the following parameters: R0 = 500 ohm, X0 = 160 ohm, R01 = 0.04 ohm and X01 = 0.1 ohm. (i) Calculate the iron loss of the transformer. (ii) Calculate the primary current at which the efficiency for the transformer will be maximum and also calculate the maximum efficiency.

Given (referred to the 220 V primary): R0=500 ΩR_0 = 500\ \Omega, X0=160 ΩX_0 = 160\ \Omega, R01=0.04 ΩR_{01} = 0.04\ \Omega, X01=0.1 ΩX_{01} = 0.1\ \Omega. Rated primary voltage V1=220V_1 = 220 V.

(i) Iron loss

Iron loss is the power taken by the core-loss resistance R0R_0 at rated voltage:

Pi=V12R0=2202500=96.8 WP_i = \frac{V_1^2}{R_0} = \frac{220^2}{500} = 96.8\ \text{W}

(X0X_0 only carries the magnetising current, which takes no real power.)

(ii) Current for maximum efficiency

Efficiency is maximum when copper loss equals iron loss:

I12R01=PiI1=PiR01=96.80.04=2420=49.19 A\begin{aligned} I_1^2 R_{01} &= P_i \\ I_1 &= \sqrt{\frac{P_i}{R_{01}}} = \sqrt{\frac{96.8}{0.04}} = \sqrt{2420} = 49.19\ \text{A} \end{aligned}

Full-load primary current is 20000/220=90.9120000/220 = 90.91 A, so maximum efficiency occurs at 49.19/90.91=0.54149.19/90.91 = 0.541, i.e. about 54% of full load.

Maximum efficiency

Assuming unity power factor (pf not given, and maximum efficiency is normally quoted at upf):

Output=V1I1cos⁡ϕ=220×49.19×1=10822.6 WTotal loss=Pi+Pcu=96.8+96.8=193.6 Wηmax=10822.610822.6+193.6×100=98.24%\begin{aligned} \text{Output} &= V_1 I_1 \cos\phi = 220 \times 49.19 \times 1 = 10822.6\ \text{W} \\ \text{Total loss} &= P_i + P_{cu} = 96.8 + 96.8 = 193.6\ \text{W} \\ \eta_{max} &= \frac{10822.6}{10822.6 + 193.6} \times 100 = 98.24\% \end{aligned}

Answer: Iron loss = 96.8 W; maximum efficiency occurs at a primary current of 49.19 A; ηmax≈\eta_{max} \approx 98.24% at unity pf.

✓ Answer checked by Claude Opus 5.5 (high effort)

All Electrical Machines I chapter 2 questions →