- Asked 2/27
- 2071 Chaitra · 12 marks
Compensator for 4/[s(s+2)], ts=2 s, Kv=2
Short answer
Lead compensator Gc(s)=4(s+2)/(s+4) cancels the plant pole at -2, placing closed-loop poles at -2±j3.464. Settling time reduces to 2 s, overshoot remains 16.3%, and velocity error constant becomes 4 s⁻¹.
Design a suitable compensator for a unity feedback system with open loop transfer function G(s) = 4/[s(s+2)] such that the settling time will become 2 seconds without change in overshoot and velocity error constant will be 2 s⁻¹.
"Without change in overshoot" means the damping ratio stays the same, while the settling time is halved. The dominant poles must move left along the same line, so a lead compensator designed by root locus is used.
Step 1: Present (uncompensated) performance
Closed loop: , so rad/s and .
- s (2% criterion)
Step 2: Desired dominant poles
Keep and make s:
Step 3: Angle deficiency
Step 4: Place the zero and pole
Let . Put the zero at to cancel the plant pole at , so the zero gives . The pole must then give :
Step 5: Gain from the magnitude condition
The compensated open loop is :
Check: characteristic equation gives , . Correct.
Step 6: Velocity error constant
This is not less than the required , so steady-state accuracy is also better.
(If must be exactly 2, the zero can be moved to with the pole at and . The angle condition still holds and , but a third closed-loop pole appears at , close to the origin. A step simulation then gives only about 3% overshoot and a settling time of about 3.4 s, so the overshoot and settling-time specifications are lost. The design above, which meets , is therefore preferred.)
Result
| Quantity | Before | After |
|---|---|---|
| 0.5 | 0.5 | |
| 16.3% | 16.3% (unchanged) | |
| 2 rad/s | 4 rad/s | |
| 4 s | 2 s | |
| 2 s | 4 s |
Answer: ; closed-loop poles , overshoot 16.3%, settling time 2 s, .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Lead compensator for 4/[s(s+2)], ts=2 s · Control Systems, chapter 7 · asked 2×
- Overshoot, settling time and error for 50/[s(s+2)] · Control Systems, chapter 3
- Compensator for 4/[s(s+2)]: Mp 16.3%, ts, Kv · Control Systems, chapter 7
- Transfer function from overshoot and settling time · Control Systems, chapter 3
- Lag compensator for 0.53/[s(1+s)(1+0.5s)], Kv = 5 · Control Systems, chapter 7
- Lead compensator for 10/[s(s+1)], ts=2 s, Mp=5% · Control Systems, chapter 7
- Lag compensator for 1.06/[s(s+1)(s+2)], ramp error < 0.2 · Control Systems, chapter 7
- z-plane design with Kv, plant 1/(s(s+2)) · Digital Control System, chapter 4
- Root-locus design: ζ = 0.5, ts = 2 s, plant 1/(s(s+1)) · Digital Control System, chapter 4 · asked 5×
- Controller design for peak time 1.2 s (ζ = 0.55), Kv · Digital Control System, chapter 4 · asked 2×
- Root-locus design: ζ = 0.5, ts = 2 s, plant 1/(s(s+2)) · Digital Control System, chapter 4 · asked 5×