Skip to main content

Constructing and interpreting X-bar and R charts

Short answer

Grand mean = 50.021 mm, mean range = 0.065 mm. Initial X-bar limits: 49.9835–50.0585 mm; R limits: 0–0.1374 mm. Sample 8 (50.12) out. After removal, revised X-bar limits 49.9728–50.0472 mm, R limits 0–0.1362 mm. The chart detects assignable causes beyond chance variation.

Samples of five shafts were taken from a production line at ten intervals. The sample means Xˉ\bar X and ranges RR (mm) are: Mean: 50.02, 49.99, 50.04, 50.01, 49.99, 50.03, 50.00, 50.12, 49.99, 50.02. Range: 0.06, 0.08, 0.05, 0.07, 0.09, 0.06, 0.04, 0.07, 0.08, 0.05. For n=5n = 5: A2=0.577A_2 = 0.577, D3=0D_3 = 0, D4=2.114D_4 = 2.114, d2=2.326d_2 = 2.326. Calculate the control limits of the Xˉ\bar X and RR charts and say whether the process is in control. If any sample is out of control, remove it and recalculate the limits. Explain the use of a control chart.

Use of a control chart

A control chart is a plot of a sample statistic against time with a centre line and upper and lower control limits (UCL, LCL) at ±3σ\pm 3\sigma. Points inside the limits show only chance variation; a point outside (or a trend) shows an assignable cause that has to be found and removed. Xˉ\bar X chart monitors the process average and RR chart monitors the spread.

Calculation (all ten samples)

Xˉˉ=500.2110=50.021 mm,Rˉ=0.6510=0.065 mm\bar{\bar X} = \frac{500.21}{10} = 50.021\ \text{mm}, \qquad \bar R = \frac{0.65}{10} = 0.065\ \text{mm}

Xˉ\bar X chart:

UCL=Xˉˉ+A2Rˉ=50.021+0.577(0.065)=50.0585UCL = \bar{\bar X} + A_2\bar R = 50.021 + 0.577(0.065) = 50.0585 LCL=50.021−0.0375=49.9835LCL = 50.021 - 0.0375 = 49.9835

RR chart:

UCLR=D4Rˉ=2.114(0.065)=0.1374,LCLR=D3Rˉ=0UCL_R = D_4\bar R = 2.114(0.065) = 0.1374, \qquad LCL_R = D_3\bar R = 0

Interpretation

All ranges (0.04 to 0.09) are below 0.1374, so the variation within samples is stable. In the Xˉ\bar X chart, sample 8 has Xˉ=50.12>50.0585\bar X = 50.12 > 50.0585 and is out of control; all others lie between 49.9835 and 50.0585.

Revised limits (without sample 8)

Xˉˉ=450.099=50.010,Rˉ=0.589=0.0644\bar{\bar X} = \frac{450.09}{9} = 50.010, \qquad \bar R = \frac{0.58}{9} = 0.0644 UCL=50.010+0.577(0.0644)=50.0472,LCL=50.010−0.0372=49.9728UCL = 50.010 + 0.577(0.0644) = 50.0472, \qquad LCL = 50.010 - 0.0372 = 49.9728 UCLR=2.114(0.0644)=0.1362,LCLR=0UCL_R = 2.114(0.0644) = 0.1362, \qquad LCL_R = 0

The remaining nine samples (49.99 to 50.04) lie within the revised limits, so the process is now in statistical control. The estimated process standard deviation is σ=Rˉ/d2=0.0644/2.326=0.0277\sigma = \bar R/d_2 = 0.0644/2.326 = 0.0277 mm.

Answer: initial Xˉ\bar X limits 49.9835 to 50.0585 mm, RR limit 0 to 0.1374 mm (sample 8 out); revised Xˉ\bar X limits 49.9728 to 50.0472 mm, RR limit 0 to 0.1362 mm.

✓ Answer checked by Claude Opus 5.5 (high effort)

All Metrology chapter 15 questions →