- 2068 Magh · 3+5 marks
Large starting current; 3-point starter
Short answer
At starting, back emf is zero so armature current is V/R_a, limited only by small armature resistance, causing dangerously high current. The 3-point starter inserts external resistance in series with the armature and gradually cuts it out as speed rises; it also provides no-volt and overload protection via NVC and OLR.
Why does the dc motor draw large current at starting? Justify it clearly and also describe the working of 3-point dc motor starter.
Why the starting current is large
The armature current is I_a = (V − E_b) / R_a. At the instant of starting the armature is at rest, so the back emf E_b = KΦN = 0. Hence
I_a(start) = V / R_a
The armature resistance R_a is very small (about 0.1 to 1 Ω). For example, with V = 220 V and R_a = 0.5 Ω, I_a = 440 A, while the rated current may be only 20 A, i.e. more than 20 times. As the motor speeds up, E_b grows and the current falls to the normal value.
This large current would damage the commutator and brushes by sparking, overheat the winding, produce a heavy torque shock on the shaft and cause a voltage dip in the supply. So a starter is used to limit the current to about 1.5 to 2 times full-load current.
Working of the 3-point starter
It has three terminals L (line), A (armature) and F (field).
L o--[OLR]--+--handle--> o--o--o--o (studs with R1..R4)
| |
+--[NVC]--- F (field) A (armature)
- Start: the handle is moved from OFF to the first stud. The supply is connected to the armature through the full starting resistance, and to the shunt field through the no-volt coil. The current is limited.
- Acceleration: as the speed rises, the back emf increases. The handle is moved to the next studs slowly, cutting the resistance out step by step.
- Run: at the last stud the whole resistance is out and the soft-iron piece on the handle is held by the electromagnet of the no-volt coil (NVC). The motor runs with full voltage.
- No-volt protection: if the supply is interrupted, the NVC loses its magnetism and the spring returns the handle to OFF, which avoids a dangerous restart.
- Overload protection: the overload release (OLR) electromagnet short-circuits the NVC on excess current, releasing the handle.
The shunt field is always in circuit from the first stud, so that the full field is available at starting and high starting torque is obtained.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- High starting current; 3-point starter · Electrical Machines, chapter 4 · asked 4×
- Working of 3-point DC motor starter · Electrical Machines, chapter 4 · asked 2×
- Need of DC motor starter and three-point starter · Electrical Machines I, chapter 4 · asked 4×
- Three terminal DC motor starter · Electrical Machine, chapter 4
- Need of starter and induction motor starting methods · Electrical Machines I, chapter 5
- Starting current; speed and % drop of shunt motor · Electrical Machines, chapter 4
- Justify synchronous motor is not self starting · Electric Machines II, chapter 2
- DC shunt motor speed at reduced voltage and starting resistance · Utilization of Electrical Energy, chapter 3
- Justify: trending method for large area forecast · Transmission and Distribution System Design, chapter 6
- Starting line current of capacitor start motor · Electric Machines II, chapter 3