- 2071 Magh (old course) · 8 marks
Voltage build-up in induction generator
Short answer
Residual rotor flux induces small stator emf, sending leading capacitor current that increases flux. This regeneratively builds voltage until the capacitor line crosses the saturated magnetisation curve. Conditions: residual magnetism, capacitance above critical value, sufficient speed, and light load.
How does voltage build up occur in an induction generator? Explain.
Voltage build-up in a self-excited induction generator is a regenerative process that starts from the residual magnetism of the rotor iron and is supported by a capacitor bank across the stator terminals.
Process
- The rotor is driven above synchronous speed by a prime mover. The small residual flux cuts the stator conductors and induces a small emf (a few volts) at the terminals.
- This emf drives a leading current through the capacitors.
- The capacitor current flows in the stator winding as a magnetising current and increases the air-gap flux in the same direction as the residual flux.
- The increased flux raises the terminal emf, which raises the capacitor current, which increases the flux further. The voltage thus builds up in steps.
- The build-up stops at the point where the capacitor line () intersects the magnetisation (saturation) curve. Beyond this point, saturation of the iron stops the rise of emf. This is the stable no-load voltage.
V
| / capacitor line
| _.-* <- stable point
| _-' /
| .' /
| / ->/
|/ / Er
+------------------> Im
Conditions for build-up
- Residual magnetism must exist in the rotor iron (if lost, flash the field with a battery).
- Capacitance must be greater than the critical value, so the capacitor line is flatter than the linear part of the magnetisation curve.
- Speed must be high enough, because the emf is proportional to speed.
- Load must not be too heavy, otherwise the voltage collapses.
With a higher capacitance the line is flatter and the final voltage is higher. A larger load needs a larger capacitance to hold the voltage.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Voltage build-up in isolated induction generator · Electrical Machines I, chapter 5
- Shunt generator voltage build-up, critical resistance and speed · Electrical Machines I, chapter 3 · asked 9×
- Starting shunt generator on no load and voltage build-up · Electrical Machines I, chapter 3
- Voltage build-up; series generator at no load · Electrical Machines, chapter 3
- Shunt generator build-up conditions, critical speed and resistance · Electrical Machines I, chapter 3
- Voltage build-up, critical resistance and speed · Electrical Machines, chapter 3 · asked 3×
- Voltage build-up at line–cable junction · High Voltage Engineering, chapter 3