Heating and cooling time constants

Short answer

Heating time constant τ_h = Gh/(Sλ) is the time to reach 63.2% of final steady temperature rise, from P dt = Gh dθ + Sλθ dt. Cooling time constant τ_c = Gh/(Sλ_c) is the time to fall to 36.8% of initial rise; τ_c is larger because λ_c < λ when ventilation stops.

What are heating time constant and cooling time constant? Explain with necessary mathematical expressions and graphs (neat sketch).

The heating time constant is the time a machine would take to reach its final steady temperature rise if heat were never lost to the surroundings, i.e. if the initial rate of rise continued. Equivalently, it is the time to reach 63.2 % of the final rise. The cooling time constant is the corresponding time during cooling: the time for the temperature rise to fall to 36.8 % of its initial value.

Heating

Let PP = losses (W), GG = mass (kg), hh = specific heat (J/kg°C), SS = cooling surface (m²), λ\lambda = specific heat dissipation (W/m²°C), θ\theta = temperature rise. In time dtdt:

P dt=Gh dθ+Sλθ dtP\,dt = G h\,d\theta + S\lambda\theta\,dt

Solving with θ=θi\theta = \theta_i at t=0t=0:

θ=θm(1−e−t/τh)+θi e−t/τh\theta = \theta_m\left(1 - e^{-t/\tau_h}\right) + \theta_i\, e^{-t/\tau_h} θm=PSλ,τh=GhSλ\theta_m = \frac{P}{S\lambda}, \qquad \tau_h = \frac{G h}{S\lambda}

Starting from cold (θi=0\theta_i = 0): θ=θm(1−e−t/τh)\theta = \theta_m(1 - e^{-t/\tau_h}). At t=τht = \tau_h, θ=0.632 θm\theta = 0.632\,\theta_m. In practice the final temperature is reached after about 4τh4\tau_h–5τh5\tau_h.

Cooling

When the machine is switched off (P=0P = 0) from a rise θi\theta_i:

0=Gh dθ+Sλcθ dt  ⇒  θ=θi e−t/τc,τc=GhSλc0 = G h\,d\theta + S\lambda_c\theta\,dt \;\Rightarrow\; \theta = \theta_i\, e^{-t/\tau_c}, \qquad \tau_c = \frac{G h}{S\lambda_c}

At t=τct = \tau_c, θ=0.368 θi\theta = 0.368\,\theta_i.

Curves

 rise                       rise
  ^   theta_m ----------     ^ theta_i
  |        _.-~~~~~          |\
  |     .-'   heating        | \   cooling
  |   /                      |  '.
  |  / 0.632 theta_m at tau  |    '-._ 0.368 at tau_c
  | /                        |        ~~--.____
  +------------------> t     +------------------> t

Comparison

PointHeating time constantCooling time constant
FormulaGh/(Sλ)Gh/(S\lambda)Gh/(Sλc)Gh/(S\lambda_c)
ValueSmallerLarger: λc<λ\lambda_c < \lambda when a self-ventilating fan stops, so τc\tau_c is about 2–3 times τh\tau_h
Typical rangeSmall machines: tens of minutes; large machines and transformers: hoursLarger than τh\tau_h
UseShort-time and overload ratingsIntermittent duty ratings

✓ Answer checked by Claude Sonnet 5.5