Heating and cooling time constants
Short answer
Heating time constant τ_h = Gh/(Sλ) is the time to reach 63.2% of final steady temperature rise, from P dt = Gh dθ + Sλθ dt. Cooling time constant τ_c = Gh/(Sλ_c) is the time to fall to 36.8% of initial rise; τ_c is larger because λ_c < λ when ventilation stops.
What are heating time constant and cooling time constant? Explain with necessary mathematical expressions and graphs (neat sketch).
The heating time constant is the time a machine would take to reach its final steady temperature rise if heat were never lost to the surroundings, i.e. if the initial rate of rise continued. Equivalently, it is the time to reach 63.2 % of the final rise. The cooling time constant is the corresponding time during cooling: the time for the temperature rise to fall to 36.8 % of its initial value.
Heating
Let = losses (W), = mass (kg), = specific heat (J/kg°C), = cooling surface (m²), = specific heat dissipation (W/m²°C), = temperature rise. In time :
Solving with at :
Starting from cold (): . At , . In practice the final temperature is reached after about –.
Cooling
When the machine is switched off () from a rise :
At , .
Curves
rise rise
^ theta_m ---------- ^ theta_i
| _.-~~~~~ |\
| .-' heating | \ cooling
| / | '.
| / 0.632 theta_m at tau | '-._ 0.368 at tau_c
| / | ~~--.____
+------------------> t +------------------> t
Comparison
| Point | Heating time constant | Cooling time constant |
|---|---|---|
| Formula | ||
| Value | Smaller | Larger: when a self-ventilating fan stops, so is about 2–3 times |
| Typical range | Small machines: tens of minutes; large machines and transformers: hours | Larger than |
| Use | Short-time and overload ratings | Intermittent duty ratings |
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Transformer heating and cooling time constants (25°C/37.5°C) · Electric Machine Design, chapter 2 · asked 3×
- Transformer heating and cooling time constants (25°C/40°C) · Electric Machine Design, chapter 2 · asked 3×
- Heating constant and 1-hour rating (400 kVA) · Electric Machine Design, chapter 2 · asked 2×
- Heating constant and 1-hour rating (40 kVA) · Electric Machine Design, chapter 2 · asked 2×
- Temperature rise-time curve under heating · Electric Machine Design, chapter 2
- Slew rate expressions and constant GBP · Advanced Electronics, chapter 2
- Thermodynamic process; constant pressure heating diagrams · Fundamental of Thermodynamics & Heat Transfer, chapter 1
- Air: PV^3 expansion, cooling, heating; total work · Fundamental of Thermodynamics & Heat Transfer, chapter 2
- Envelope detector and choice of time constant · Communication Systems, chapter 2 · asked 2×