Natural vs artificial convection; heating curve
Short answer
Natural convection relies on density differences, giving low heat transfer; artificial convection uses fans/pumps for high coefficients and compact machines. The temperature rise-time curve is θ = θ_m (1 - e^{-t/τ}) + θ_i e^{-t/τ}, with θ_m = P/(Sλ) and τ = Gh/(Sλ).
Differentiate between natural and artificial convections in brief. Also derive an expression for the temperature rise-time curve for an electrical machine.
Convection is the transfer of heat from a hot surface by a moving fluid (air, hydrogen, oil). It is the main way heat leaves an electrical machine. Depending on what drives the fluid, it is called natural or artificial (forced) convection.
Natural vs artificial convection
| Point | Natural convection | Artificial (forced) convection |
|---|---|---|
| Fluid motion caused by | Density difference: hot fluid rises, cold fluid replaces it | External agency: fan, blower or pump |
| Velocity of coolant | Low | High, controlled |
| Heat transfer coefficient | Low (air about 10–15 W/m²°C) | High; rises with air velocity, roughly |
| Dependence on surface position | Depends on height and orientation of surface | Little dependence |
| Extra equipment and losses | None | Fans/pumps; extra cost and power loss |
| Reliability | Very high; no moving parts | Depends on fan/pump |
| Machine size for a rating | Larger | Smaller (higher output per kg) |
| Examples | Small enclosed motors, ONAN transformers | Self- and separately-ventilated motors, ONAF/OFAF transformers, hydrogen-cooled alternators |
The dissipation coefficient for forced air flow is often written , where is the air velocity in m/s. Doubling the cooling therefore lets a much larger loss be removed for the same rise.
Temperature rise–time curve of an electrical machine
Assumptions: the machine is a homogeneous body with uniform temperature; losses are constant; heat dissipated is proportional to the temperature rise.
Notation: = mass (kg), = specific heat (J/kg°C), = cooling surface (m²), = specific heat dissipation (W/m²°C), = temperature rise at time .
In time , heat produced = heat stored + heat dissipated:
Let (final steady rise) and (heating time constant). The equation becomes
Separating variables and integrating from at :
From cold: .
rise
^ theta_m - - - - - - - - - - - - -
| ___....-------~~~~
| _.-''
| .-' 0.632 theta_m at t = tau
| /
| /
| /
+---|------|------|------|------> t
tau 2tau 3tau 4tau
Cooling (losses removed): , giving with .
Link between convection and the curve
- Forced convection raises . This lowers both the final rise and the time constant .
- For the same permitted rise, a forced-cooled machine can carry larger losses, i.e. a higher output from the same frame.
- In self-ventilated machines the fan stops at standstill, so and the cooling time constant is longer than the heating time constant.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Temperature rise-time curve under heating · Electric Machine Design, chapter 2
- Machine temperature after one hour of heating · Electric Machine Design, chapter 2
- Transformer heating and cooling time constants (25°C/37.5°C) · Electric Machine Design, chapter 2 · asked 3×
- Transformer heating and cooling time constants (25°C/40°C) · Electric Machine Design, chapter 2 · asked 3×
- Temperature rise and tubes for 500 kVA transformer · Electric Machine Design, chapter 3 · asked 2×
- True/False: ampere conductors and temperature rise · Electric Machine Design, chapter 5
- Temperature rise of machine field winding · Basic Electrical Engineering, chapter 1
- Natural versus artificial seasoning · Civil Engineering Materials, chapter 7
- Natural and forced convection compared · Heat Transfer, chapter 3
- Natural/artificial lighting, daylight factor numerical · Building Technology, chapter 1