- 2083 Baisakh (new course) · 3 marks
Capacitor for quadrature currents (7+j5 Ω)
Short answer
Set Xc so that auxiliary current leads main current by 90°. Compute main winding angle θm=35.54°, required auxiliary branch angle -54.46°, Xc=21.1 Ω, giving C=150.9 µF.
A 250 W, 230 V, 50 Hz capacitor start motor has following impedances at standstill. Zm = 7+j5 Ω and Za = 11.5+j5 Ω. Find the value of the capacitor to be connected in series with the auxiliary winding to give a quadrant phase displacement between the currents in two windings. Draw the circuit and phasor diagram for motor.
For quadrature, must lead by , so the auxiliary branch angle must be less than that of the main winding.
Given: , , V, Hz.
Currents: A, A.
Circuit: Phasors:
o---+--------+ I_a (54.5 deg)
| | ^
Z_m Z_a | 90 deg
| | -------+-------> V
230V| [C] \
| | v I_m (-35.5 deg)
| CS
o---+--------+
Answer: () in series with the auxiliary winding.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Capacitor for quadrature currents (4.5+j3.7 Ω) · Electric Machines II, chapter 3 · asked 2×
- Capacitor for quadrature currents (4.5+j3.5 Ω) · Electric Machines II, chapter 3
- Starting line current of capacitor start motor · Electric Machines II, chapter 3
- Split-phase motor winding currents at starting · Electric Machines II, chapter 3
- Increase in starting torque with 1000 μF capacitor · Electric Machines II, chapter 3
- Capacitor start motor operating principle · Electric Machines II, chapter 3 · asked 2×
- Delta capacitor per phase for 50 kW motor · Basic Electrical Engineering, chapter 8
- Short note: Capacitor start and run motor · Electrical Machines, chapter 7 · asked 2×
- Currents and efficiency of 132/11 kV transformer at 5 MW · Electrical Machines I, chapter 2 · asked 3×
- True/false: auxiliary winding construction · Electrical Machine, chapter 7