- Asked 2/30
- 2081 Baisakh · 8 marks
- 2080 Bhadra · 8 marks
Super chlorination; overflow rate 5000 L/m2/h
Short answer
Super‑chlorination is used during epidemics, for new mains, or poor‑quality water; break‑point chlorination gives stable free residual, oxidizes ammonia, and removes tastes. For overflow rate 5000 L/m²/h (0.1389 cm/s) at 20°C: 0.06 mm vs=0.3215 cm/s, removed 100%; 0.03 mm vs=0.0804 cm/s, removed 57.9%.
When is super chlorination recommended in a water supply scheme? Write about the advantages of break point chlorination. A settling tank is designed for an overflow rate of 5000 liters per m per hour. What percentage of particles of diameter 0.06 mm and 0.03 mm will be removed in this tank? Temperature of water is 20°C and specific gravity of particles is 2.65.
When super-chlorination is recommended
Super-chlorination (a dose far above the demand, followed by de-chlorination) is used:
- during epidemics of cholera, typhoid, hepatitis, etc.;
- when a new main, pipe or tank is commissioned or repaired;
- when the raw water is of highly variable or very poor quality, or the plant is overloaded;
- when the contact time is short (so a high dose compensates);
- for emergency or camp supplies and when pre-treatment is poor. The dose is 3 to 15 mg/l and the excess is removed by sulphur dioxide, sodium thiosulphate or activated carbon.
Advantages of break-point chlorination
- Oxidises ammonia, organic matter and iron/manganese completely, which removes most tastes and odours.
- Kills pathogens and algae far more effectively than combined chlorine, including organisms that resist chloramines.
- Gives a stable free residual which protects the distribution system against recontamination.
- The chlorine demand is fully satisfied and known, so the dose can be controlled accurately.
Numerical: removal in the settling tank
Overflow rate l/m²/h m³/m²/h:
At 20 °C, cm²/s, , cm/s². By Stokes' law, .
Particle 0.06 mm (0.006 cm):
(Stokes' law holds). Since > cm/s, the particles are removed 100 %.
Particle 0.03 mm (0.003 cm):
. As , the removal is
Answer: 0.06 mm particles: 100 % removed; 0.03 mm particles: 57.9 % removed.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Overflow rate 4000 L/m2/h at 10°C · Water Supply Engineering, chapter 6 · asked 2×
- Super/break point chlorination; bleaching 20 MLD · Water Supply Engineering, chapter 6
- Settling tank 30 m x 3 m, 0.03 mm at 25°C; 0.025 mm at 20°C · Water Supply Engineering, chapter 6 · asked 3×
- Super vs break point chlorination; residual · Water Supply Engineering, chapter 6
- Break point chlorination; bleaching powder 500000 L · Water Supply Engineering, chapter 6
- Break point chlorination; pH and temperature effects · Water Supply Engineering, chapter 6 · asked 2×
- Settling basin design for 0.2 mm particles · Hydro Power, chapter 5
- Settling basin design for 0.15 mm particles · Hydro Power, chapter 5
- Domestic water supply; septic tank and soak pit · Building Technology, chapter 12
- Rate analysis: 12.5 mm plaster 1:5, per m² · Estimating and Costing, chapter 4 · asked 3×