- 2073 Bhadra · 8 marks
Water conveyance and application efficiencies
Short answer
Conveyance efficiency = Q_field / Q_div = 110/150 = 73.33%. Application efficiency: stored = 3168 - 445 = 2723 m³, applied = 3168 m³, ηa = 85.95%. Storage efficiency: needed = 3300 m³, ηs = 2723/3300 = 82.52%. Distribution efficiency: mean depth d=1.3 m, y=0.1 m, ηd = 92.31%.
A stream of 150 liter per second was diverted from canal and 110 liter per second was delivered to the field. An area of 2.2 hectares was irrigated in 8 hrs. Effective depth of root zone was 1.5 m. The runoff loss in the field was 445 m³. The depth of water penetration varied linearly from 1.5 m at the head end of the field to 1.1 m at the tail end. Available moisture holding capacity of the soil is 200 mm per meter depth of soil. Determine the water conveyance efficiency, water application efficiency, water storage efficiency and water distribution efficiency. Irrigation was started at a moisture extraction level of 50%.
Given: l/s, l/s, area ha m, time h, root zone m, runoff m, penetration depth 1.5 m (head) to 1.1 m (tail), available moisture = 200 mm/m, irrigation started at 50% depletion of available moisture.
1. Water conveyance efficiency
2. Water applied to the field
Water stored in the root zone. The penetration depth (1.5 m at the head, 1.1 m at the tail) does not exceed the root depth of 1.5 m, so deep percolation is nil (assumed). Hence
Water application efficiency
3. Water storage efficiency. Water needed to bring the root zone back to field capacity (50% of available moisture was used):
4. Water distribution efficiency. Depth varies linearly between 1.5 m and 1.1 m, so mean depth m and the average numerical deviation m.
Answer: , , , .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Lined canal capacity and irrigable area · Irrigation and Drainage Engineering, chapter 4 · asked 2×
- Field capacity from applied water data · Irrigation and Drainage Engineering, chapter 2
- Canal drop structure, Q 5, FSL 110.5 · Irrigation and Drainage Engineering, chapter 7
- Storage capacity, depth and water at outlet · Irrigation and Drainage Engineering, chapter 2
- AMC, RAM, depth and interval; headworks depth · Irrigation and Drainage Engineering, chapter 2 · asked 2×
- Drainage canal for 5 ha paddy field · Irrigation and Drainage Engineering, chapter 9 · asked 2×
- Runoff and effective rainfall, 4-hr storm, 80 km2 · Engineering Hydrology, chapter 3 · asked 2×
- Surface runoff with initial loss and phi-index, 100-min storm · Engineering Hydrology, chapter 3
- Time area method for runoff hydrograph · Engineering Hydrology, chapter 7
- Runoff from a 20 ha built-up area · Sanitary Engineering, chapter 2
All Irrigation and Drainage Engineering chapter 2 questions →