- 2081 Chaitra · 8 marks
Conventional ASP design, 0.104 m³/s
Short answer
Flow 8985.6 m³/d, aeration tank volume V=Q⋅S₀/(F/M⋅X)=3295 m³. Use liquid depth 4.0 m, provide two tanks each 40 m × 10.5 m × 4.5 m (depth includes 0.5 m freeboard).
Design a conventional activated sludge plant to treat settled domestic sewage with diffused air aeration system for the given data: Sewage discharge = 0.104 m³/s; BOD5 of settled sewage = 220 mg/l; Effluent BOD allowed = 30 mg/l; F/M ratio = 0.2; MLSS = 3000 mg/l.
Data and design basis
Conventional ASP (plug flow, diffused air). The aeration tank volume follows from the food-to-micro-organism ratio:
Data: settled-sewage mg/l, effluent BOD mg/l, per day, MLSS mg/l. The return sludge ratio is also checked (SVI assumed).
Step 1: Design flow
Step 2: Volume of aeration tank
(units: in m³/day and , in mg/l = g/m³.)
Step 3: Dimensions
Provide 2 tanks (so one can be taken out of service), each with area m² and L : B about 4 : 1:
Adding 0.5 m free board, the tank depth is 4.5 m. The size of each tank is .
Step 4: Checks
BOD removal efficiency , within the usual 85-95% of a conventional ASP.
Answer: aeration tank volume m³ (detention 8.8 h, depth 4.0 m); provide 2 tanks, each in plan with liquid depth 4.0 m (tank depth 4.5 m).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Conventional ASP design, population 1,00,000 · Sanitary Engineering, chapter 7
- Conventional ASP design, population 126000 · Sanitary Engineering, chapter 7
- Conventional ASP design, population 50,000 · Sanitary Engineering, chapter 7 · asked 2×
- Conventional ASP design, 96 lpcd · Sanitary Engineering, chapter 7 · asked 2×
- Activated sludge and ASP treatment process · Sanitary Engineering, chapter 7
- 1-day BOD 300 mg/l to 5-day at 30°C · Sanitary Engineering, chapter 5