- 2076 Baisakh · 8 marks
Conventional ASP design, population 1,00,000
Short answer
Flow 15000 m³/d, aeration tank volume 5000 m³. Liquid depth 4.0 m, provide two tanks each 50 m × 12.5 m × 4.5 m. HRT 8.0 h, volumetric loading 0.60 kg BOD/m³/d.
Design a conventional activated sludge plant to treat settled domestic sewage with diffused air aeration system for the following data; (Design up to dimension of Aeration tank): Population = 1,00,000; Per capita sewage contribution = 150 lit/d; BOD5 of sewage = 200 mg/l; Effluent BOD5 = 30 mg/l; F/M = 0.2 day⁻¹; MLSS = 3000 mg/l.
Data and design basis
Conventional ASP (plug flow, diffused air). The aeration tank volume follows from the food-to-micro-organism ratio:
Data: mg/l, effluent mg/l (efficiency 85%), /day, MLSS mg/l. Only the aeration tank is designed.
Step 1: Design flow
Step 2: Volume of aeration tank
(units: in m³/day and , in mg/l = g/m³.)
Step 3: Dimensions
Provide 2 tanks (so one can be taken out of service), each with area m² and L : B about 4 : 1:
Adding 0.5 m free board, the tank depth is 4.5 m. The size of each tank is .
Step 4: Checks
Answer: aeration tank volume m³ (detention 8.0 h, depth 4.0 m); provide 2 tanks, each in plan with liquid depth 4.0 m (tank depth 4.5 m).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Conventional ASP design, population 50,000 · Sanitary Engineering, chapter 7 · asked 2×
- Conventional ASP design, population 126000 · Sanitary Engineering, chapter 7
- Conventional ASP design, 96 lpcd · Sanitary Engineering, chapter 7 · asked 2×
- Conventional ASP design, 0.104 m³/s · Sanitary Engineering, chapter 7
- Activated sludge and ASP treatment process · Sanitary Engineering, chapter 7
- Service reservoir of 30 m diameter, 1,00,000 population · Water Supply Engineering, chapter 7