Conventional ASP design, population 1,00,000

Short answer

Flow 15000 m³/d, aeration tank volume 5000 m³. Liquid depth 4.0 m, provide two tanks each 50 m × 12.5 m × 4.5 m. HRT 8.0 h, volumetric loading 0.60 kg BOD/m³/d.

Design a conventional activated sludge plant to treat settled domestic sewage with diffused air aeration system for the following data; (Design up to dimension of Aeration tank): Population = 1,00,000; Per capita sewage contribution = 150 lit/d; BOD5 of sewage = 200 mg/l; Effluent BOD5 = 30 mg/l; F/M = 0.2 day⁻¹; MLSS = 3000 mg/l.

Data and design basis

Conventional ASP (plug flow, diffused air). The aeration tank volume follows from the food-to-micro-organism ratio:

FM=Q S0V X ⇒ V=Q S0(F/M) X\frac{F}{M}=\frac{Q\,S_0}{V\,X}\ \Rightarrow\ V=\frac{Q\,S_0}{(F/M)\,X}

Data: S0=200S_0=200 mg/l, effluent BOD5=30BOD_5=30 mg/l (efficiency 85%), F/M=0.2F/M=0.2/day, MLSS =3000=3000 mg/l. Only the aeration tank is designed.

Step 1: Design flow

Q=100000×150/1000=15000.0 m3/dayQ = 100000\times150/1000 = 15000.0\ \text{m}^3/\text{day}

Step 2: Volume of aeration tank

V=15000.0×2000.2×3000=5000.0 m3V = \frac{15000.0\times 200}{0.2\times 3000} = 5000.0\ \text{m}^3

(units: QQ in m³/day and S0S_0, XX in mg/l = g/m³.)

Step 3: Dimensions

Adopt liquid depth =4.0 m (usual range 3-4.5 m)Plan area A=V4.0=1250.0 m2\begin{aligned} \text{Adopt liquid depth } &= 4.0\ \text{m (usual range 3-4.5 m)}\\ \text{Plan area } A &= \frac{V}{4.0} = 1250.0\ \text{m}^2 \end{aligned}

Provide 2 tanks (so one can be taken out of service), each with area 625.0625.0 m² and L : B about 4 : 1:

B=625.04=12.50 m (adopt 12.5 m),L=625.012.5=50.0 m (adopt 50 m)B=\sqrt{\frac{625.0}{4}} = 12.50\ \text{m (adopt 12.5 m)},\qquad L=\frac{625.0}{12.5} = 50.0\ \text{m (adopt 50 m)}

Adding 0.5 m free board, the tank depth is 4.5 m. The size of each tank is 50 m×12.5 m×4.5 m50\ \text{m}\times 12.5\ \text{m}\times 4.5\ \text{m}.

Step 4: Checks

Hydraulic retention time=VQ=5000.015000.0×24=8.0 h (usual 4-8 h; accepted)Volumetric loading=Q S0V×1000=0.60 kg BOD/m3/day (usual 0.3-0.6)\begin{aligned} \text{Hydraulic retention time} &= \frac{V}{Q} = \frac{5000.0}{15000.0}\times 24 = 8.0\ \text{h}\ (\text{usual 4-8 h; accepted})\\ \text{Volumetric loading} &= \frac{Q\,S_0}{V\times 1000} = 0.60\ \text{kg BOD/m}^3\text{/day}\ (\text{usual 0.3-0.6}) \end{aligned}

Answer: aeration tank volume ≈5000\approx 5000 m³ (detention 8.0 h, depth 4.0 m); provide 2 tanks, each 50 m×12.5 m50\ \text{m}\times 12.5\ \text{m} in plan with liquid depth 4.0 m (tank depth 4.5 m).