Conventional ASP design, 96 lpcd

Short answer

Aeration tank volume 3200 m³ from F/M ratio; detention time 8 h; two tanks each 40 m × 10 m × 4.5 m (liquid depth 4 m, freeboard 0.5 m).

Design a conventional activated sludge treatment plant to treat the domestic sewage with diffused air aeration with the following data. (Design up to dimensions of aeration tank only) Population = 1,00,000; Per capita sewage flow = 96 liters/day; Settled sewage BOD5 = 200 mg/L; Food/micro-organisms = 0.3; Concentration of microorganism (MLSS) = 2000 mg/L.

Data and design basis

Conventional ASP (plug flow, diffused air). The aeration tank volume follows from the food-to-micro-organism ratio:

FM=Q S0V X ⇒ V=Q S0(F/M) X\frac{F}{M}=\frac{Q\,S_0}{V\,X}\ \Rightarrow\ V=\frac{Q\,S_0}{(F/M)\,X}

Data: settled-sewage S0=200S_0=200 mg/l, F/M=0.3F/M=0.3/day, MLSS =2000=2000 mg/l. Only the aeration tank is designed.

Step 1: Design flow

Q=100000×96/1000=9600.0 m3/dayQ = 100000\times96/1000 = 9600.0\ \text{m}^3/\text{day}

Step 2: Volume of aeration tank

V=9600.0×2000.3×2000=3200.0 m3V = \frac{9600.0\times 200}{0.3\times 2000} = 3200.0\ \text{m}^3

(units: QQ in m³/day and S0S_0, XX in mg/l = g/m³.)

Step 3: Dimensions

Adopt liquid depth =4.0 m (usual range 3-4.5 m)Plan area A=V4.0=800.0 m2\begin{aligned} \text{Adopt liquid depth } &= 4.0\ \text{m (usual range 3-4.5 m)}\\ \text{Plan area } A &= \frac{V}{4.0} = 800.0\ \text{m}^2 \end{aligned}

Provide 2 tanks (so one can be taken out of service), each with area 400.0400.0 m² and L : B about 4 : 1:

B=400.04=10.00 m (adopt 10.0 m),L=400.010.0=40.0 m (adopt 40 m)B=\sqrt{\frac{400.0}{4}} = 10.00\ \text{m (adopt 10.0 m)},\qquad L=\frac{400.0}{10.0} = 40.0\ \text{m (adopt 40 m)}

Adding 0.5 m free board, the tank depth is 4.5 m. The size of each tank is 40 m×10.0 m×4.5 m40\ \text{m}\times 10.0\ \text{m}\times 4.5\ \text{m}.

Step 4: Checks

Hydraulic retention time=VQ=3200.09600.0×24=8.0 h (usual 4-8 h; accepted)Volumetric loading=Q S0V×1000=0.60 kg BOD/m3/day (usual 0.3-0.6)\begin{aligned} \text{Hydraulic retention time} &= \frac{V}{Q} = \frac{3200.0}{9600.0}\times 24 = 8.0\ \text{h}\ (\text{usual 4-8 h; accepted})\\ \text{Volumetric loading} &= \frac{Q\,S_0}{V\times 1000} = 0.60\ \text{kg BOD/m}^3\text{/day}\ (\text{usual 0.3-0.6}) \end{aligned}

Answer: aeration tank volume ≈3200\approx 3200 m³ (detention 8.0 h, depth 4.0 m); provide 2 tanks, each 40 m×10.0 m40\ \text{m}\times 10.0\ \text{m} in plan with liquid depth 4.0 m (tank depth 4.5 m).