- 2079 Chaitra · 8 marks
Conventional ASP design, population 126000
Short answer
Design flow 20160 m³/d, aeration tank volume 6720 m³ (detention 8.0 h). Provide three tanks each 47 m × 12.0 m × 4.5 m. Checks: HRT 8.0 h, volumetric loading 0.60 kg BOD/m³/d, return sludge ratio 43%, horizontal velocity 0.10 m/min.
Design a conventional activated sludge treatment plant in your Municipality to treat the domestic sewage with diffused air aeration with the following data. Population = 1,26,000; Per capita sewage flow = 160 lpcd; Settled sewage BOD5 = 200 mg/L; Effluent BOD5 required = 15 mg/L; Take F/M: 0.2 and MLSS = 3000 mg/L. Also check HRT, Volumetric Loading, Return Sludge ratio, Horizontal Velocity.
Data and design basis
Conventional ASP (plug flow, diffused air). The aeration tank volume follows from the food-to-micro-organism ratio:
Data: settled-sewage mg/l; effluent mg/l (efficiency ); /day; MLSS mg/l. Assumed: SVI ml/g for the return sludge ratio.
Step 1: Design flow
Step 2: Volume of aeration tank
(units: in m³/day and , in mg/l = g/m³.)
Step 3: Dimensions
Provide 3 tanks (so one can be taken out of service), each with area m² and L : B about 4 : 1:
Adding 0.5 m free board, the tank depth is 4.5 m. The size of each tank is .
Step 4: Checks
Answer: aeration tank volume m³ (detention 8.0 h, depth 4.0 m); provide 3 tanks, each in plan with liquid depth 4.0 m (tank depth 4.5 m).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Conventional ASP design, population 50,000 · Sanitary Engineering, chapter 7 · asked 2×
- Conventional ASP design, population 1,00,000 · Sanitary Engineering, chapter 7
- Conventional ASP design, 96 lpcd · Sanitary Engineering, chapter 7 · asked 2×
- Conventional ASP design, 0.104 m³/s · Sanitary Engineering, chapter 7
- Activated sludge and ASP treatment process · Sanitary Engineering, chapter 7
- Degree of treatment, domestic + industrial · Sanitary Engineering, chapter 6
- Design pipes AB, BC; 160 lpcd, peak factor 3 · Water Supply Engineering, chapter 7