Critical DO location, industry 1.8 m³/s

Short answer

Critical deficit occurs at 99.7 km (5.77 days) using base-e constants (kd=0.25, kr=0.11). Mixed BOD5=32.0 mg/l, ultimate BOD=44.9 mg/l, initial deficit=1.06 mg/l. DO after 1 and 3 days is effectively zero (formula gives negative), river turns anaerobic.

An industry is going to be established in an urban area near the river side. The river water and industrial effluent characteristics are as follows:

Industrial effluentRiver water
Flow (m³/s)1.822
DO (mg/l)08.7
BOD5, 20°3506.0

kd, 20° = 0.25 d⁻¹; kr, 20° = 0.11 d⁻¹; DO saturation = 9.1 mg/l. At what location in the river critical DO deficit would occur if the flow velocity in the river is 0.20 m/s? Also find out DO at the end of 1 and 3 days.

Rates are taken as base ee: kd=0.25k_d=0.25/day, kr=0.11k_r=0.11/day (20°C, so no temperature correction). Since kr<kdk_r<k_d, the ratio f=kr/kd=0.44<1f=k_r/k_d=0.44<1. DOsat=9.1DO_{sat}=9.1 mg/l.

Step 1: Mixing

Q=1.8+22=23.8 m3/sBOD5mix=1.8×350+22×623.8=32.02 mg/lDOmix=1.8×0+22×8.723.8=8.04 mg/lD0=9.1−8.04=1.06 mg/lL0=BOD51−e−5kd=32.021−e−1.25=44.87 mg/l\begin{aligned} Q &= 1.8+22 = 23.8\ \text{m}^3/\text{s}\\ BOD_5^{mix} &= \frac{1.8\times 350+22\times 6}{23.8} = 32.02\ \text{mg/l}\\ DO_{mix} &= \frac{1.8\times 0+22\times 8.7}{23.8} = 8.04\ \text{mg/l}\\ D_0 &= 9.1-8.04 = 1.06\ \text{mg/l}\\ L_0 &= \frac{BOD_5}{1-e^{-5k_d}} = \frac{32.02}{1-e^{-1.25}} = 44.87\ \text{mg/l} \end{aligned}

Step 2: Critical time and location

tc=1kr−kdln⁡[krkd{1−D0(kr−kd)kdL0}]=5.770 dayst_c = \frac{1}{k_r-k_d}\ln\left[\frac{k_r}{k_d}\left\{1-\frac{D_0(k_r-k_d)}{k_dL_0}\right\}\right] = 5.770\ \text{days} Dc=kdL0kre−kdtc=24.10 mg/lxc=v tc=0.20×86400×5.770/1000=99.7 km\begin{aligned} D_c &= \frac{k_dL_0}{k_r}e^{-k_dt_c} = 24.10\ \text{mg/l}\\ x_c &= v\,t_c = 0.20\times 86400\times 5.770/1000 = 99.7\ \text{km} \end{aligned}

Step 3: DO after 1 and 3 days

Dt=kdL0kr−kd(e−kdt−e−krt)+D0e−krtD_t = \frac{k_dL_0}{k_r-k_d}\left(e^{-k_dt}-e^{-k_rt}\right)+D_0e^{-k_rt}
t (days)DtD_t (mg/l)DO=9.1−DtDO = 9.1 - D_t (mg/l)
110.33-1.23
320.52-11.42

Answer: the critical deficit occurs about 99.7 km downstream (tc=5.770t_c=5.770 days). The computed deficits (10.33 and 20.52 mg/l) exceed the saturation value 9.1 mg/l, so the DO after 1 day and 3 days is effectively zero (the formula gives -1.23 and -11.42 mg/l, which is physically not possible): the river would turn anaerobic, and the effluent needs treatment.

✓ Answer checked by Claude Opus 5.5 (high effort)