- 2072 Magh · 4 marks
Design discharge of rural combined sewer
Short answer
Peak sewage is 0.0422 m3/s using 45 lpcd and peak factor 2.7. With tc=30 min, intensity is 19 mm/hr; storm runoff is 1.900 m3/s. Combined design discharge is 1.942 m3/s.
A population of 30000 is residing in a rural area of 60 hectares. If the average coefficient of runoff for this area is 0.60, time required to the entry port is 25 minutes and the time of travel from the entry port to the section of sewer under consideration for design is 5 minutes. What will be the design discharge for a combined sewer at the section to be considered if the average flow of sewage in rural is 45 lpcd and peak factor is 2.7?
Design discharge of a combined sewer = peak dry weather sewage flow + storm runoff.
Step 1: Peak sewage flow
Average flow = 45 lpcd (given as the sewage flow), peak factor 2.7.
Step 2: Time of concentration and intensity
No rainfall formula is given, so I use the common empirical form mm/hr (assumed):
Step 3: Storm water (Rational formula)
Step 4: Design discharge
Answer: Design discharge = 1.942 m³/s (the sewage is only about 2% of it).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Circular combined sewer, 60 ha · Sanitary Engineering, chapter 3
- Combined sewer section, 85 ha area · Sanitary Engineering, chapter 3
- Design discharge, separate and combined · Sanitary Engineering, chapter 2
- Wet weather discharge, combined sewer · Sanitary Engineering, chapter 2
- Sewer diameter for a 2.5 sq km area · Sanitary Engineering, chapter 3
- Combined circular sewer, 35 ha · Sanitary Engineering, chapter 3
- Design discharge 2040, Ilam rural municipality · Water Supply Engineering, chapter 3 · asked 2×
- Time area method for runoff hydrograph · Engineering Hydrology, chapter 7
- Average demand, village survey 2013, design 25 years · Water Supply Engineering, chapter 3 · asked 2×
- Canal discharge for dry and wet crops (30000/40000 ha) · Irrigation and Drainage Engineering, chapter 2 · asked 2×