- 2068 Magh (old course) · 8 marks
Design discharge, separate and combined
Short answer
Separate system sewage flow is 0.1875 m3/s, requiring about a 0.525 m sewer at slope 1 in 500. Combined system adds storm flow 0.475 m3/s, giving 0.662 m3/s and about a 0.90 m sewer.
Determine the design discharge for separate and combined systems of a small town with projected population of 45000 residing over an area of 20 hectares. Rate of water supply = 150 lpcd; Runoff coefficient = 0.45; Time of concentration = 30 mins; Sewer slope = 1 in 500; Manning's n = 0.013.
Assumptions
- 80% of water supplied becomes sewage; peak factor = 3; infiltration neglected.
- No rainfall formula is given, so mm/hr is assumed for the intensity at .
(a) Separate system (sewage only)
Design the sewer running full (, ). From Manning's formula for a full circular pipe, :
Adopt m (standard size). Full velocity m/s, which is above 0.6 m/s.
(b) Combined system
Adopt m. Full velocity m/s (below the 3 m/s maximum).
Answer: Separate system: m³/s, sewer about m. Combined system: m³/s, sewer about m, both at slope 1 in 500.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Design discharge of rural combined sewer · Sanitary Engineering, chapter 2
- Wet weather discharge, combined sewer · Sanitary Engineering, chapter 2
- Separate vs combined sewerage systems · Sanitary Engineering, chapter 1 · asked 4×
- Runoff from a 20 ha built-up area · Sanitary Engineering, chapter 2
- Combined sewer section, 85 ha area · Sanitary Engineering, chapter 3
- Storm water from a 45 ha catchment · Sanitary Engineering, chapter 2
- Design pipes AB and BC, 20,000 population, f = 0.04 · Water Supply Engineering, chapter 7
- Balancing reservoir: town 1.2 million, 45 L/head · Water Supply Engineering, chapter 7 · asked 2×
- Balancing reservoir: village 600 population, 65 lpcd · Water Supply Engineering, chapter 7
- Population 2090 by three methods, 110 lpcd · Water Supply Engineering, chapter 3 · asked 2×