- 2079 Baisakh · 10 marks
Biaxial column 400x600, Fe500
Short answer
Short column with Pu=1000 kN, Mux=125, Muy=200 kNm is safe. Provide 12-20 mm bars (Asc=3770 mm2, p=1.57%) and 8 mm ties at 300 mm c/c; biaxial interaction ratio is 0.95.
Determine the reinforcement in short column having 4 m length fixed in both sides with bi-axially loaded having the following parameters: Size of column = 400 mm x 600 mm; Factored load, Pu = 1000 kN; Factored moment Mux = 125 kNm; Factored moment Muy = 200 kNm; M25 concrete and Fe500 steel
Data and assumptions
- Column 400 mm (width ) × 600 mm (depth ); kN; MPa, MPa. Clear cover 40 mm (IS 456 cl. 26.4.2.1), 8 mm ties.
- Moments: about major axis (x-x) = 125 kN·m; about minor axis (y-y) = 200 kN·m.
- Both ends fixed: m. kN·m acts about the major axis (depth 600 mm), kN·m about the minor axis (depth 400 mm).
- Sizes are given as with ; moments act about the major axis (depth ) and about the minor axis (depth ).
Slenderness
| Axis | (mm) | Dimension (mm) | dim | Type |
|---|---|---|---|---|
| x-x (about major) | 2600 | 600 | 4.33 | short |
| y-y (about minor) | 2600 | 400 | 6.50 | short |
| Both ratios are below 12, so the column is short; no additional moment is required. |
Minimum eccentricity (cl. 25.4)
- About x-x: mm (min. 20 mm); adopt 28.0 mm; kN·m
- About y-y: mm (min. 20 mm); adopt 21.3 mm; kN·m
Design moments
- Design moments: kN·m, kN·m (not less than the minimum-eccentricity values).
Longitudinal reinforcement
Bars are chosen so that lies between 0.8% (minimum) and 4% (practical maximum; IS 456 cl. 26.5.3.1 allows 6%). The uniaxial capacities , at are read from the SP-16 interaction charts for rectangular sections; here they are computed by strain compatibility with the IS 456 stress block and the design stress-strain curve of steel (same basis as the charts), with effective cover .
| Trial | (%) | ||||||
|---|---|---|---|---|---|---|---|
| 10-20 φ | 1.31 | 0.097 | 395.3 | 267.7 | 0.260 | 1.10 | 1.007 ✗ |
| 16-16 φ | 1.34 | 0.093 | 418.8 | 256.0 | 0.258 | 1.10 | 1.028 ✗ |
| 12-20 φ | 1.57 | 0.097 | 457.9 | 277.6 | 0.246 | 1.08 | 0.950 ✓ |
Check
kN , so (IS 456 cl. 39.6; linear between 1.0 at 0.2 and 2.0 at 0.8).
The interaction condition is satisfied; the section is safe.
Provide 12-20 mm bars ( mm², ), within 0.8% to 4%.
Lateral ties
- Diameter mm → provide 8 mm.
- Pitch (least lateral dimension, , 300 mm) mm → provide 8 mm ties @ 300 mm c/c.
Detailing
CROSS-SECTION 400 x 600
+-------------------------+
| o o o o |
| |
| |
| o o |
| |
| |
| |
| o o |
| |
| |
| o o o o |
+-------------------------+
o = 20 mm bars, ties 8 mm @ 300 c/c
Answer: 400 × 600 mm column with 12-20 mm longitudinal bars () and 8 mm ties @ 300 mm c/c.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Biaxial column 400x600, 1500 kN · Design of RCC Structure, chapter 10
- Biaxial column 500x600, 1300 kN · Design of RCC Structure, chapter 10
- Biaxial column 400x500, equal steel all sides · Design of RCC Structure, chapter 10
- Fixed-end column 4 m, 1000 kN · Design of RCC Structure, chapter 10
- Biaxial short square column, 800 kN · Design of RCC Structure, chapter 10
- Shear reinforcement, 250x500 beam, Fe500 · Design of RCC Structure, chapter 5
- Design steps of axially loaded brick column · Concrete Technology and Masonry Structure, chapter 8
- Built-up column with battens, 4 m, 1000 kN · Design of Steel and Timber Structure, chapter 6 · asked 2×
- Built-up laced column, 10 m, 1000 kN · Design of Steel and Timber Structure, chapter 6 · asked 4×
- Box column of teak planks, 400 kN · Design of Steel and Timber Structure, chapter 11