Short answer

Harmonic voltages Vnm=4×230/(nπ) V; load impedances Zn=√[R²+(nωL-1/(nωC))²] give currents. Up to 5th: i0(t)=28.31 sin(314.16t+67.25°)+3.69 sin(942.48t-81.30°)+1.15 sin(1570.8t-85.50°) A. Fundamental RMS=20.02 A; total power=1632.5 W, fundamental power=1602.6 W.

A single-phase full-bridge inverter has RLC load of R = 4 Ω, L = 35 mH and C = 155 µF. The dc input voltage is 230 V and the output frequency is 50 Hz. i) Find an expression for load current up to fifth harmonic. Also, calculate ii) Rms value of fundamental load current. iii) The power absorbed by load and the fundamental power.

For a square-wave full-bridge inverter, the output voltage contains only odd harmonics, v0=∑4Vsnπsin⁡nωtv_0 = \sum \frac{4V_s}{n\pi}\sin n\omega t. Each harmonic current is found by dividing by the load impedance at that harmonic, and the currents are added (superposition).

Given: R=4 ΩR = 4\ \Omega, L=35L = 35 mH, C=155 μC = 155\ \muF, Vs=230V_s = 230 V, f=50f = 50 Hz, ω=314.16\omega = 314.16 rad/s.

i) Load current up to the fifth harmonic

Vnm=4Vsnπ=292.85n VZn=R2+(nωL−1nωC)2,θn=tan⁡−1nωL−1/(nωC)R\begin{aligned} V_{nm} &= \frac{4V_s}{n\pi} = \frac{292.85}{n}\ \text{V} \\ Z_n &= \sqrt{R^2 + \Big(n\omega L - \frac{1}{n\omega C}\Big)^2}, \qquad \theta_n = \tan^{-1}\frac{n\omega L - 1/(n\omega C)}{R} \end{aligned}
nnVnmV_{nm} (V)XLX_L (Ω)XCX_C (Ω)XX (Ω)ZnZ_n (Ω)θn\theta_nInmI_{nm} (A)
1292.8511.0020.54−9.5410.35−67.25°28.31
397.6232.996.8526.1426.4581.30°3.69
558.5754.984.1150.8751.0385.50°1.15

The current is in=(Vnm/Zn)sin⁡(nωt−θn)i_n = (V_{nm}/Z_n)\sin(n\omega t - \theta_n). The fundamental sees a capacitive load, so it leads:

i0(t)=28.31sin⁡(314.16t+67.25∘)+3.69sin⁡(942.48t−81.30∘)+1.15sin⁡(1570.8t−85.50∘) Ai_0(t) = 28.31\sin(314.16t + 67.25^\circ) + 3.69\sin(942.48t - 81.30^\circ) + 1.15\sin(1570.8t - 85.50^\circ)\ \text{A}

ii) RMS value of fundamental load current

I1=28.312=20.02 AI_{1} = \frac{28.31}{\sqrt2} = 20.02\ \text{A}

iii) Power absorbed by the load and fundamental power

RMS load current (harmonics up to the 5th):

I3=3.6912=2.61 A,I5=1.1482=0.81 AI0=20.022+2.612+0.812=20.20 A\begin{aligned} I_3 &= \frac{3.691}{\sqrt2} = 2.61\ \text{A}, \qquad I_5 = \frac{1.148}{\sqrt2} = 0.81\ \text{A} \\ I_0 &= \sqrt{20.02^2 + 2.61^2 + 0.81^2} = 20.20\ \text{A} \end{aligned} P0=I02R=20.202×4=1632.5 WP1=I12R=20.022×4=1602.6 W\begin{aligned} P_0 &= I_0^2R = 20.20^2\times4 = 1632.5\ \text{W} \\ P_1 &= I_1^2R = 20.02^2\times4 = 1602.6\ \text{W} \end{aligned}

(Including all higher harmonics changes P0P_0 only slightly, to about 1633.6 W.)

Answer: I1,rms=20.02I_{1,rms} = 20.02 A; load power ≈1632.5\approx 1632.5 W; fundamental power =1602.6= 1602.6 W.