Series inductor for di/dt limit
Short answer
At firing, di/dt = Vm/(Ls+L). With Vm = 311 V and limit 500 A/s, Ls+L >= 0.622 H; load L = 0.1 H, so Ls >= 0.522 H.
Fig.1c shows the single phase half-wave controlled rectifier with di/dt protection provided by the series inductor. The load is a purely inductive having an inductance of 100 mH. Calculate the value of Ls so that di/dt is limited to 500A/sec. [Figure: Vs = 220 V source, series inductor Ls, thyristor and the load in series]
In the circuit the series inductor and the load inductance are in series with the thyristor. At the instant of firing the current is zero, so the whole supply voltage appears across the total inductance and
The worst case is firing at the peak of the supply. Assumption: 220 V is the rms value.
Answer: H (522 mH).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Three-phase single-way controlled rectifier, R load · Power Electronics, chapter 3 · asked 3×
- Single-phase half-wave thyristor rectifier, R load · Power Electronics, chapter 2
- Three-phase single-way controlled rectifier, α = 60° · Power Electronics, chapter 3 · asked 3×
- Three-phase single-way controlled rectifier, α = 30° · Power Electronics, chapter 3 · asked 4×
- Three-phase single-way controlled rectifier, α = 90° · Power Electronics, chapter 3 · asked 4×
- Three-phase single-way controlled rectifier, α = π/6 · Power Electronics, chapter 3
- 3-phase half controlled bridge: no-load speed, firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×
- SCR half-wave rectifier fired at 30° · Advanced Electronics, chapter 7
- SCR analogy; half-wave rectifier for 1 A average · Advanced Electronics, chapter 7
- SCR half-wave rectifier numerical (200 V peak) · Advanced Electronics, chapter 7