- 2076 Asoj · 6 marks
Open and closed Brayton cycles
Short answer
Open cycle takes in fresh air, compresses, burns fuel internally, exhausts to atmosphere, simple and light. Closed cycle recirculates the same fluid, heats externally, uses a cooler, allows any fuel and no blade fouling but requires large heat exchangers.
Explain the closed and open Brayton cycle.
The Brayton (Joule) cycle is the ideal cycle for gas turbine plants. It has four processes: isentropic compression (1–2), constant-pressure heat addition (2–3), isentropic expansion (3–4) and constant-pressure heat rejection (4–1). Its ideal efficiency is .
Open Brayton cycle
Air in Fuel
1 --> [C] -2-> [CC] -3-> [T] -4-> Exhaust
\==================/ ==> Gen
- Atmospheric air is drawn in, compressed, mixed with fuel and burnt directly in the combustion chamber; products expand in the turbine and are exhausted to the atmosphere.
- Heat rejection 4–1 takes place in the atmosphere, so a fresh charge is used every cycle.
- Advantages: simple, light, compact, low cost, quick start; no cooler needed. Used in aircraft engines and most power-station gas turbines.
- Disadvantages: working fluid is combustion gas, so turbine blades suffer deposits, erosion and corrosion; only clean fuels (gas, light oil) can be used; output depends on atmospheric conditions; filters needed.
Closed Brayton cycle
Heater (external heat)
+--> [Heat exch.] -3-> [T] -4-+
|2 |
[C] <-1- [Cooler] <------------+
\=======shaft=======/ ==> Gen
- The same working fluid (air, helium, CO₂, nitrogen) circulates continuously. Heat is supplied externally in a heat exchanger (by burning any fuel, or from a nuclear reactor) and rejected in a pre-cooler before the compressor.
- Advantages: clean working fluid, so no blade fouling or erosion; any fuel (coal, nuclear) can be used; higher pressure level gives smaller components and better part-load efficiency (output controlled by changing pressure level); gases with better properties (helium) can be used.
- Disadvantages: needs large heat exchangers and cooler, so heavier, costlier and slower to start; requires cooling water; leakage of working fluid must be prevented.
| Point | Open cycle | Closed cycle |
|---|---|---|
| Working fluid | Fresh air each cycle | Same fluid recirculated |
| Heat supply | Internal combustion | External heat exchanger |
| Heat rejection | To atmosphere | In pre-cooler |
| Fuel | Clean gas/oil only | Any fuel, nuclear |
| Size/weight | Small, light | Large, heavy |
| Blade fouling | Yes | No |
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Regenerative cycle: 4 MPa, 400°C, open heater · Power Plant Equipment, chapter 7 · asked 2×
- Open cycle gas turbine with intercooling · Power Plant Equipment, chapter 6
- Open cycle gas turbine on heavy oil · Power Plant Equipment, chapter 6
- Combined cycle merits, demerits and designs · Power Plant Equipment, chapter 8 · asked 2×
- Combined cycle advantages and three designs · Power Plant Equipment, chapter 8 · asked 2×
- Combined cycle combinations and advantages · Power Plant Equipment, chapter 8
- Brayton cycle; Atkinson and Stirling cycles · Internal Combustion Engines, chapter 1
- Ideal Brayton cycle with 30 MW heat input · Fundamental of Thermodynamics & Heat Transfer, chapter 6 · asked 2×
- Ideal Brayton cycle: diagrams and efficiency · Fundamental of Thermodynamics & Heat Transfer, chapter 6 · asked 2×
- Ideal Brayton cycle: net work per kg and efficiency · Fundamental of Thermodynamics & Heat Transfer, chapter 6