Regenerative cycle: 4 MPa, 400°C, open heater
Short answer
Cycle efficiency ≈ 37.5%. Using steam table data: h1=3214.4, h2=2686.3, h3=2144.5 kJ/kg; pump work 4.23 kJ/kg; bleed fraction m=0.1654 from open FWH energy balance. Net work 976.1 kJ/kg, heat input 2605.7 kJ/kg.
On a regenerative cycle, steam leaves the boiler and enters the turbine at 4 MPa, 400°C. After expansion to 400 kPa, some of the steam is extracted from the turbine to heat the feed water in an open feed water heater. The pressure in the feed water heater is 400 kPa, and the water leaving it is saturated liquid at 400 kPa. The steam not extracted expands to 10kPa. Determine the cycle efficiency. [Refer the attached table for the properties of steam]
Assumptions: ideal regenerative Rankine cycle with one open feed water heater; turbine and pumps isentropic; exit of heater is saturated liquid at 400 kPa; pump work included. Property values are taken from the steam tables (IAPWS-IF97 values, as in Cengel's tables).
1
+--------+------>+---------------+ +-----+
| Boiler | | Turbine |===| Gen |
| + S/H | +---------------+ +-----+
+--------+ | m kg (2) | (1-m) kg (3)
^ 7 v v
| +-----------+ +-----------+
+--------+ 6 | Open FWH | | Condenser |
| Pump 2 |<---| (mixing) | +-----------+
+--------+ +-----------+ | 4
^ 5 |
+--------+ |
| Pump 1 |<--------+
+--------+
Steam table data
| Pressure | (°C) | (m³/kg) | ||||
|---|---|---|---|---|---|---|
| 10 kPa | 45.81 | 191.81 | 2392.07 | 0.6492 | 7.4997 | 0.001010 |
| 400 kPa | 143.61 | 604.72 | 2133.33 | 1.7766 | 5.1188 | 0.001084 |
At 4 MPa, 400 °C (superheated): kJ/kg, kJ/kg K.
State 2 (bled steam, 400 kPa, )
State 3 (exhaust, 10 kPa, )
Pumps
Bled steam fraction (energy balance on open FWH)
:
Work and heat (per kg of steam at boiler exit)
Cycle efficiency
Answer: cycle efficiency (bled fraction kg per kg of steam).
T
^ 1
| /|
| f----------g |
| / |
| 7 |
| 6 . . . . . . . 2 bleed (m kg)
| / |
| 5 |
| 4-----------------3 (1-m) kg
+-------------------------> s
4-5 pump 1, 5 and 2 mix in FWH -> 6,
6-7 pump 2, 7-f-g-1 boiler,
1-2-3 turbine, 3-4 condenser
For comparison, a simple Rankine cycle between the same limits gives about 35.3%, so one open heater raises the efficiency by about 2 percentage points.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Regenerative scheme with open feed water heater · Power Plant Equipment, chapter 7
- Reheat cycle: 4 MPa, 400°C · Power Plant Equipment, chapter 7
- Throttled reheat cycle with 50 bar steam · Power Plant Equipment, chapter 7
- Feed water heating combined circuit and reasons · Power Plant Equipment, chapter 8
- Regenerative gas turbine: 1 to 6.9 bar · Power Plant Equipment, chapter 6
- Reheat Rankine cycle: 20 MPa, 500°C · Power Plant Equipment, chapter 7
- Steam turbine 10 MPa, 550°C: isentropic efficiency · Fundamental of Thermodynamics & Heat Transfer, chapter 5
- Define saturation pressure, saturated liquid, etc.; sketch · Fundamental of Thermodynamics & Heat Transfer, chapter 3
- Simple Rankine plant 2 MPa / 20 kPa: efficiency, power · Fundamental of Thermodynamics & Heat Transfer, chapter 6
- Boiler trial heat balance sheet · Applied Thermodynamics, chapter 1