Skip to main content

Brush excitation system

Short answer

An excitation system supplies controlled DC field current. In the brush system, a shaft-driven DC main exciter (with a pilot exciter) supplies field current through brushes and slip rings. The AVR adjusts the exciter field to hold terminal voltage. It is simple but requires brush and commutator maintenance.

What is excitation system? Explain the brush excitation system with neat diagram.

An excitation system supplies and controls the DC current in the rotor field winding of a synchronous generator, so as to hold terminal voltage and control reactive power.

Brush (DC) excitation system

In a brush excitation system the field current is produced outside the rotor (by a DC exciter or by rectifiers) and is fed to the rotating field winding through brushes and slip rings. The classic form uses a shaft-mounted DC generator (main exciter), often with a smaller pilot exciter.

 Pilot     Main        Main alternator
 exciter   exciter    +-------------------+
 +----+    +----+     | rotor field       |
 | PE |--->| ME |=B/S=>| winding    stator |--> 3-ph
 +----+    +----+     |            wndg   |    out
   |   field  ^       +-------------------+
   |   rheo.  |                 |
   +----------+--<-- AVR <-- PT-+
 <====== common shaft (turbine) ======>
 B/S = brushes and slip rings

Components and working

  1. Pilot exciter: small self-excited DC shunt generator on the same shaft. It supplies the field of the main exciter.
  2. Main exciter: separately excited DC generator on the shaft. Its armature output (a few hundred volts DC) feeds the alternator field.
  3. Brushes and slip rings: carry the main exciter output to the rotating field winding of the alternator.
  4. Automatic voltage regulator (AVR): senses terminal voltage through a PT, compares it with the reference and adjusts the main exciter field current (through a rheostat, amplidyne or magnetic amplifier).
  5. Field breaker and discharge resistor: isolate and de-excite the field quickly during internal faults.

When terminal voltage falls (more load or lagging pf), the AVR raises the main exciter field current, EfdE_{fd} rises, alternator field current rises and VtV_t returns to the set value.

A modern variant of brush excitation is the static exciter, where thyristor rectifiers fed from the generator terminals supply the field through slip rings.

Merits and demerits

MeritsDemerits
Simple, proven designBrush and commutator wear; regular maintenance
Field can be de-excited quickly through slip ringsSparking, carbon dust; fire risk
Easy field current measurementCommutation limits exciter rating (large units)
Low cost for small and medium unitsSlow response (large TET_E) for DC exciters

✓ Answer checked by Claude Opus 5.5 (high effort)

All Power Plant Equipment chapter 3 questions →