Skip to main content

Lead compensator for 4/[s(s+2)], Mp≤16.3%, ts≤2 s

Short answer

Cancel the plant pole at -2 with a compensator zero; for 30° lead, place the pole at -4. Gain Kc=4 gives Gc(s)=4(s+2)/(s+4). Closed-loop ωn=4 rad/s, ζ=0.5 yields Mp=16.3% and ts=2 s.

Design a lead compensator for a system having open loop transfer function 4/[s(s+2)], such that the designed system should have %Mp ≤ 16.3% and settling time (ts) ≤ 2 sec.

A lead compensator is designed by the root locus method: find the desired dominant poles, find the angle the compensator must add, place its zero and pole, then find its gain.

Step 1: Desired closed-loop poles

Peak overshoot:

Mp=e−πζ/1−ζ2=0.163ζ=−ln⁡0.163π2+(ln⁡0.163)2=1.8143.628=0.5\begin{aligned} M_p &= e^{-\pi\zeta/\sqrt{1-\zeta^2}} = 0.163 \\ \zeta &= \frac{-\ln 0.163}{\sqrt{\pi^2 + (\ln 0.163)^2}} = \frac{1.814}{3.628} = 0.5 \end{aligned}

Settling time (2% criterion):

ts=4ζωn=2  ⇒  ζωn=2,ωn=20.5=4 rad/st_s = \frac{4}{\zeta\omega_n} = 2 \;\Rightarrow\; \zeta\omega_n = 2,\quad \omega_n = \frac{2}{0.5} = 4\ \text{rad/s} sd=−ζωn±jωn1−ζ2=−2±j3.464s_d = -\zeta\omega_n \pm j\omega_n\sqrt{1-\zeta^2} = -2 \pm j3.464

Step 2: Uncompensated system

Closed-loop characteristic equation: s2+2s+4=0s^2 + 2s + 4 = 0, so ωn=2\omega_n = 2, ζ=0.5\zeta = 0.5.

  • Mp=16.3%M_p = 16.3\% (already correct), ts=40.5×2=4t_s = \dfrac{4}{0.5\times2} = 4 s (too slow).
  • Kv=lim⁡s→0s 4s(s+2)=2 s−1K_v = \lim_{s\to0} s\,\dfrac{4}{s(s+2)} = 2\ \text{s}^{-1}.

So the poles must move further left along the same ζ=0.5\zeta = 0.5 line, which needs a lead compensator.

Step 3: Angle deficiency

At sd=−2+j3.464s_d = -2 + j3.464:

∠sd=180∘−tan⁡−13.4642=120∘∠(sd+2)=90∘∠G(sd)=−(120∘+90∘)=−210∘ϕ=−180∘−(−210∘)=30∘\begin{aligned} \angle s_d &= 180^\circ - \tan^{-1}\frac{3.464}{2} = 120^\circ \\ \angle (s_d + 2) &= 90^\circ \\ \angle G(s_d) &= -(120^\circ + 90^\circ) = -210^\circ \\ \phi &= -180^\circ - (-210^\circ) = 30^\circ \end{aligned}

The compensator must add +30∘+30^\circ at sds_d.

Step 4: Locate zero and pole (bisector method)

Let Gc(s)=Kcs+zs+pG_c(s) = K_c\dfrac{s+z}{s+p}. At point P (−2,j3.464)(-2, j3.464) draw a horizontal line PA to the left and the line PO to the origin. Angle APO =120∘= 120^\circ. Draw its bisector PB, then two lines at ±ϕ/2=±15∘\pm\phi/2 = \pm15^\circ from PB; they cut the real axis at the zero and the pole.

            P (-2, j3.46)
           /|\ 
          / | \  bisector +-15 deg
         /  |  \
 -------x---o--x------x-----o---> Re
      -5.46 -2.93  -2        0
       pole  zero  plant   plant

The lines from P make angles 255∘255^\circ (zero) and 225∘225^\circ (pole) with the positive real axis:

z=2+3.464tan⁡75∘=2+0.928=2.93p=2+3.464tan⁡45∘=2+3.464=5.46\begin{aligned} z &= 2 + \frac{3.464}{\tan 75^\circ} = 2 + 0.928 = 2.93 \\ p &= 2 + \frac{3.464}{\tan 45^\circ} = 2 + 3.464 = 5.46 \end{aligned}

Check: zero angle 75∘75^\circ, pole angle 45∘45^\circ, net lead =30∘= 30^\circ.

Step 5: Gain

Kc=∣sd∣ ∣sd+2∣ ∣sd+5.46∣4 ∣sd+2.93∣=4×3.464×4.8994×3.586=4.73Gc(s)=4.73 s+2.93s+5.46\begin{aligned} K_c &= \frac{|s_d|\,|s_d+2|\,|s_d+5.46|}{4\,|s_d+2.93|} = \frac{4 \times 3.464 \times 4.899}{4 \times 3.586} = 4.73 \\ G_c(s) &= 4.73\,\frac{s+2.93}{s+5.46} \end{aligned}

Kv=lim⁡s→0s GcG=4.73×4×2.932×5.46=5.07 s−1K_v = \lim_{s\to0} s\,G_cG = \dfrac{4.73\times4\times2.93}{2\times5.46} = 5.07\ \text{s}^{-1}.

Closed-loop poles: −2±j3.464-2 \pm j3.464 and −3.46-3.46. The closed-loop zero at −2.93-2.93 is not close enough to the third pole to cancel it, so a step simulation gives Mp≈21%M_p \approx 21\%, ts≈2.04t_s \approx 2.04 s, slightly above the limits.

Step 6: Final design (pole–zero cancellation)

To meet Mp≤16.3%M_p \le 16.3\% exactly, place the zero on the plant pole at −2-2. The pole must give 90∘−30∘=60∘90^\circ - 30^\circ = 60^\circ:

p=2+3.464tan⁡60∘=4,4Kc=∣sd∣ ∣sd+4∣=4×4=16⇒Kc=4p = 2 + \frac{3.464}{\tan 60^\circ} = 4, \qquad 4K_c = |s_d|\,|s_d+4| = 4 \times 4 = 16 \Rightarrow K_c = 4 Gc(s)=4(s+2)s+4,GcG=16s(s+4)G_c(s) = \frac{4(s+2)}{s+4}, \qquad G_cG = \frac{16}{s(s+4)}

Closed loop: s2+4s+16=0s^2 + 4s + 16 = 0, so ωn=4\omega_n = 4, ζ=0.5\zeta = 0.5.

QuantityUncompensatedBisector designFinal design
Gc(s)G_c(s)14.73s+2.93s+5.464.73\frac{s+2.93}{s+5.46}4s+2s+44\frac{s+2}{s+4}
MpM_p16.3%about 21%16.3%
tst_s4 sabout 2.04 s2 s
KvK_v25.074

Answer: lead compensator Gc(s)=4(s+2)s+4G_c(s) = \dfrac{4(s+2)}{s+4} gives Mp=16.3%M_p = 16.3\% and ts=2t_s = 2 s with Kv=4 s−1K_v = 4\ \text{s}^{-1}.

✓ Answer checked by Claude Opus 5.5 (high effort)

All Control Systems chapter 7 questions →