V-curve and inverted V-curve
Short answer
A V-curve plots armature current versus field current at constant load, minimum at unity pf. An inverted V-curve plots power factor versus field current, peaking at unity pf, showing how excitation controls reactive power.
What do you mean by V-curve and inverted V-curve for a synchronous motor? Explain with a neat diagram.
V-curve
A V-curve of a synchronous motor is the graph of armature current against field current , at constant supply voltage and constant load (mechanical output). The curve has the shape of the letter V.
- The lowest point of each curve is at unity power factor, where the armature current is minimum.
- To the left (under-excited) the current lags the voltage; the pf is lagging, and increases as is reduced.
- To the right (over-excited) the current leads; the pf is leading, and increases as is increased.
- Curves are drawn for no load, half load, full load, etc. A higher load gives a curve higher up, and its minimum point moves to a larger field current.
- The dotted line joining the minima is the unity power factor line; the region to its left is lagging pf and the region to its right is leading pf.
Ia
|\ /
| \ full load /
| \ /
| \ half load /
| \ \ / /
| \ \ no / /
| \ \ load/ /
+-------\----*---/------> If
lagging unity pf leading
(under) (min Ia) (over)
Inverted V-curve
The inverted V-curve is the plot of power factor against field current at constant load. The power factor rises as the field current increases from the under-excited region, reaches its maximum value of unity at the same field current at which the V-curve is at its minimum, and then falls again (now leading) as the field current is raised further. The shape is like an inverted V.
pf
1.0| /\
| / \
| / \
| / \
+-----------------> If
lag unity lead
These curves show that a synchronous motor can be operated at any power factor by changing its excitation, so it is used for power factor correction (as a synchronous condenser).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- 3.3 kV synchronous motor back emf · Electrical Machines, chapter 6 · asked 2×
- Effect of excitation on synchronous motor · Electrical Machines, chapter 6 · asked 5×
- Synchronous motor not self-starting; starting methods · Electrical Machines, chapter 6 · asked 2×
- Starting methods of synchronous motor · Electrical Machines, chapter 6 · asked 2×
- Hunting; loaded operation of synchronous motor · Electrical Machines, chapter 6
- Synchronous motor: pf when input rises to 1500 kW · Electrical Machines, chapter 6
- V-curve and inverted V-curve · Electrical Machine, chapter 6
- Synchronous motor features, applications and excitation · Electric Machines II, chapter 2
- Effect of excitation on synchronous motor · Electrical Machine, chapter 6 · asked 6×
- Synchronous motor drawing lagging and leading current · Electric Machines II, chapter 2 · asked 4×