Synchronous motor drawing lagging and leading current
Short answer
A synchronous motor's power factor is controlled by field excitation at constant load. Under-excitation (Eb < V) gives lagging current and inductive behaviour; over-excitation (Eb > V) gives leading current, acting as a capacitor. This is demonstrated by V-curves, where lowest point is unity pf.
A synchronous motor can operate as both inductive and capacitive characteristics. Justify this statement with relevant phasor diagrams. (Explain how a three-phase synchronous motor can be operated to draw lagging as well as leading current from the source.)
A synchronous motor runs at constant speed whatever its excitation. For a constant load (constant input power ), changing the field current changes the back emf , and hence the magnitude and power factor of the armature current. So the same motor can behave as an inductive (lagging) or a capacitive (leading) load.
Motor equation (per phase, neglected):
The resultant voltage drives the current, which lags by 90°.
1. Under-excitation (): lagging pf (inductive)
V
O-------------->
\`-. /
\ `-. / Er = jIXs
\ `/
I \ Eb (short)
(lags V)
- ; the motor draws a lagging current.
- The field is too weak, so the armature takes a lagging (magnetising) current from the supply to make up the missing flux. The motor then behaves like an induction motor or an inductor.
2. Normal excitation (): unity pf
- Field current is just enough for the required flux; current is in phase with and is minimum for that load.
O--------------> V
O--------> I (in phase)
\ /
Eb / Er
3. Over-excitation (): leading pf (capacitive)
I (leads V)
^ V
| O---------->
| \ .
| \ . Er
| Eb (long)
- ; the resultant makes the current lead .
- The motor supplies reactive power to the system and acts as a capacitor. Running at no load like this, it is called a synchronous condenser, used for power-factor improvement and voltage control.
Summary
| Excitation | vs (approx.) | Current | pf | Acts as |
|---|---|---|---|---|
| Under | Large | Lagging | Inductor | |
| Normal | Minimum | Unity | Resistor | |
| Over | Large | Leading | Capacitor |
These variations are shown by the V-curves (armature current vs field current at constant load), whose lowest point is at unity pf.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Synchronous motor features and lagging/leading operation · Electric Machines II, chapter 2
- Leading kVAR supplied by synchronous motor · Electric Machines II, chapter 2
- Justify synchronous motor is not self starting · Electric Machines II, chapter 2
- Load characteristics and capacitive load voltage rise · Electric Machines II, chapter 1 · asked 3×
- Excitation emf of motor drawing 160 A · Electric Machines II, chapter 2
- Split phase motor added resistance and capacitance · Electric Machines II, chapter 3
- Synchronous generator load characteristics, capacitive load · Electrical Machines, chapter 6
- Effect of excitation on synchronous motor · Electrical Machine, chapter 6 · asked 6×
- Single-phase current source inverter with AC motor · Power Electronics, chapter 5
- Sync motor back emf at 0.5 pf leading · Electrical Machine, chapter 6