Skip to main content

Brick and mortar: 20 cm wall, 3.4 m

Short answer

Required bricks of minimum 7.5 N/mm² with M2 (1:6) mortar. Effective height 2.55 m gives slenderness ratio 12.75, ks=0.784; eccentricity ratio 1/12 allows 25% increase. Base stress 0.565 N/mm² gives required basic compressive stress 0.576 N/mm².

A wall 20 cm thick, using modular bricks, carries at the top a load of 100 kN/m having resultant eccentricity of 1/12. The wall is 5 m long between cross walls and is of 3.4 m clear height between RCC slabs at top and bottom. What should be the required strength of brick and grade of mortar? Assume that joints are not raked.

Data and assumptions

  • Wall 20 cm thick, modular bricks, joints not raked. Load 100 kN/m at top, e/t=1/12e/t=1/12.
  • Wall 5 m long between cross walls, clear height 3.4 m between RCC slabs (slab thickness not given, H=3.4H=3.4 m).
  • RCC slabs give lateral and rotational restraint (Table 4 Sl. 1).
  • Design code: IS 1905:1987 (Tables 4 to 10); NBC 109 follows the same permissible-stress method.
  • Brick masonry unit weight 19 kN/m3^3 (IS 875 Part 1); modular brick, height/width ≤0.75\le 0.75, so kp=1k_p=1.

Step 1: Effective height, length and slenderness ratio (IS 1905 cl. 4.3, 4.4, 4.6)

Height between slab centres H=3.40H = 3.40 m. Effective height hef=0.75H=0.75×3.40=2.550h_{ef} = 0.75 H = 0.75\times3.40 = 2.550 m. Effective length (wall supported by a cross wall at each end, Table 5 Sl. 3) Lef=1.0L=5.00L_{ef} = 1.0L = 5.00 m. The lesser value governs:

SR=heft=2.5500.200=12.75 (<27, Table 7, cement mortar)SR = \frac{h_{ef}}{t} = \frac{2.550}{0.200} = 12.75\ (<27,\ \text{Table 7, cement mortar})

Step 2: Design load per metre run at the base

Self weight=t Hc γ=0.200×3.40×19=12.92 kN/mP=100.00+12.92=112.92 kN/m\begin{aligned} \text{Self weight} &= t\,H_c\,\gamma = 0.200\times3.40\times19 = 12.92\ \text{kN/m}\\ P &= 100.00 + 12.92 = 112.92\ \text{kN/m} \end{aligned}

Stress on the wall:

σ=PA=112.92×103200×103 mm2/m=0.565 N/mm2\sigma = \frac{P}{A} = \frac{112.92\times10^3}{200\times10^3\ \text{mm}^2/\text{m}} = 0.565\ \text{N/mm}^2

Step 3: Reduction factors

  • Stress reduction factor ksk_s (Table 9, SR=12.75SR=12.75, e/t=0.083e/t=0.083, by linear interpolation) =0.784= 0.784
  • Area reduction factor kak_a (cl. 5.4.1.2): area per metre 0.20 m2^2 is not less than 0.2 m2^2, so ka=1.0k_a = 1.0
  • Shape factor kp=1.0k_p = 1.0 (modular bricks, height/width ≤0.75\le 0.75, Table 10)
  • Since e/t>1/24e/t > 1/24, a 25 percent increase in permissible stress is allowed (cl. 5.4.1.4 a), factor 1.25

Step 4: Required basic compressive stress

σ≤fb ks ka kp×1.25⇒fb≥0.5650.784×1.0×1.0×1.25=0.576 N/mm2\sigma \le f_b\,k_s\,k_a\,k_p\times1.25 \Rightarrow f_b \ge \frac{0.565}{0.784\times1.0\times1.0\times1.25} = 0.576\ \text{N/mm}^2

(Without the 25 percent increase the requirement would be fb≥0.720f_b \ge 0.720 N/mm2^2.)

Step 5: Strength of brick and grade of mortar (IS 1905 Table 8)

Smallest standard unit strength giving fb≥0.576f_b \ge 0.576 N/mm2^2:

Mortar (IS 1905 Table 1)Min. unit strength (N/mm²)Table 8 fbf_b (N/mm²)
M2 (cement:sand 1:6)7.50.59
M1 (cement:sand 1:5)7.50.74
H2 (cement:sand 1:4)7.50.74
H1 (cement:sand 1:3)7.50.75

Answer: use bricks of crushing strength not less than 7.5 N/mm2^2 with mortar M2 (cement:sand 1:6) (fb=0.59f_b = 0.59 N/mm2^2 ≥\ge 0.576). Other combinations in the table are also acceptable; a stronger mortar allows a weaker brick.

✓ Answer checked by Claude Opus 5.5 (high effort)

All Concrete Technology and Masonry Structure chapter 8 questions →