Design of transformer core
Short answer
Core design fixes net iron area Ai = φm/Bm with φm = Et/(4.44f). Limb is stepped to fill the circular winding; stacking factor ≈0.9; yoke area 15–20% larger than limb for hot-rolled steel. Window area derived from output equation.
Discuss in brief about the design of core of transformer.
Core design fixes the net iron area, the shape of the limb section, the stampings, and the yoke, so that the flux is carried at the chosen flux density with low loss and low cost.
1. Net iron area
From :
is chosen according to the steel: about 1.1–1.45 Wb/m² for hot-rolled, 1.35–1.75 Wb/m² for CRGO.
2. Shape of limb section
Windings are circular, so the limb is made stepped to fill the circle of diameter :
| Core section | Net area | Largest stamping |
|---|---|---|
| Square | ||
| Cruciform (2-step) | ||
| 3-stepped | ||
| 4-stepped |
(stacking factor 0.9). More steps use the circle better and shorten the mean turn, but increase labour. Square and cruciform cores are used for small transformers; 3 to 7 steps for large ones.
3. Stampings and stacking
- Thin silicon-steel laminations (0.35 mm or less), insulated by varnish or oxide, to reduce eddy loss.
- Stacking factor (net/gross area) ≈ 0.9.
- Joints are staggered (overlapped) or mitred at 45° (for CRGO) to reduce reluctance and loss at the corners.
- Large cores have cooling ducts between packets.
4. Yoke
- With hot-rolled steel, yoke area is made 15–20% larger than limb area to lower yoke flux density, loss and magnetising current.
- Yoke is usually rectangular: depth , height .
- With CRGO, yoke area is equal to limb area (stepped yoke).
5. Window
The output equation gives the window area, , with = 2 to 4. The core frame then follows: , , (3-phase) or (1-phase).
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Core type versus shell type transformer · Electric Machine Design, chapter 3 · asked 3×
- Leakage reactance of core type transformer · Electric Machine Design, chapter 3 · asked 3×
- Requirements of transformer core material · Electric Machine Design, chapter 1
- Per unit resistance drop of core type transformer · Electric Machine Design, chapter 3
- Core, turns and conductors of 5 kVA transformer · Electric Machine Design, chapter 3
- Design: 100 kVA single phase, square core · Electric Machine Design, chapter 3
- Transformer no-load and load operation, constant core flux · Electrical Machines I, chapter 2 · asked 5×
- T/F: rural design, transformer size first · Transmission and Distribution System Design, chapter 7
- Design: 550 m head plant, transformer quotation · Power Plant Design, chapter 4 · asked 3×
- T/F: urban design, transformer location first · Transmission and Distribution System Design, chapter 7