- 2069 Asar · 10 marks
Hardy-Cross network discharge AB, BC, AD, CD
Short answer
Use Hardy-Cross method with Hazen-Williams equation. After iterations, final discharges: AB = 20.97 lps, BC = 0.97 lps, AD = 34.03 lps, CD = 9.03 lps from D to C.
Calculate the discharge in pipes AB, BC, AD and CD for the water distribution network given below by using Hardy-cross method. The available data of network are as follows:
| Pipe | Length (in meter) | Diameter (in mm) |
|---|---|---|
| AB | 400 | 300 |
| BC | 300 | 200 |
| AD | 500 | 400 |
| CD | 500 | 300 |
Hazen Williams coefficient as 100 for all pipes. Assume other necessary data suitably.
[Figure: loop ABCD; 55 lps enters at A, 20 lps leaves at B, 10 lps leaves at C, 25 lps leaves at D.]
Hardy-Cross method balances the flows in a loop by repeatedly applying a correction until the algebraic sum of head losses around the loop is zero.
Data
Hazen-Williams with , C = 100. Inflow 55 lps at A; outflow 20 lps at B, 10 lps at C and 25 lps at D. Correction:
Take clockwise flow (A→B→C→D) as positive.
Trial flows (satisfying continuity at every node)
AB = 35 lps (A→B), BC = 15 lps (B→C), CD = 5 lps (C→D), AD = 20 lps (A→D, anticlockwise, so negative). Check: A: 35 + 20 = 55 ✓; B: 35 − 20 = 15 ✓; C: 15 − 10 = 5 ✓; D: 5 + 20 = 25 ✓.
Iteration 1
| Pipe | Q (lps) | h = rQ^1.852 (m) | h/Q |
|---|---|---|---|
| AB | +35.00 | +0.597 | 0.0171 |
| BC | +15.00 | +0.672 | 0.0448 |
| CD | +5.00 | +0.020 | 0.0041 |
| AD | -20.00 | -0.065 | 0.0033 |
m, , so lps. Corrected flows (the correction is added to clockwise pipes and subtracted from AD): AB = 25.45, BC = 5.45, CD = -4.55, AD = 29.55 lps.
Iteration 2
| Pipe | Q (lps) | h = rQ^1.852 (m) | h/Q |
|---|---|---|---|
| AB | +25.45 | +0.331 | 0.0130 |
| BC | +5.45 | +0.103 | 0.0189 |
| CD | -4.55 | -0.017 | 0.0038 |
| AD | -29.55 | -0.134 | 0.0046 |
m, lps.
Further iterations
Corrections: -0.662, -0.026, -0.000, -0.000 lps; the process stops when ΔQ is negligible (< 0.01 lps).
Final discharges
| Pipe | Discharge (lps) | Direction |
|---|---|---|
| AB | 20.97 | A → B |
| BC | 0.97 | B → C |
| AD | 34.03 | A → D |
| CD | 9.03 | D → C |
Checks: at B, 20.97 = 20 + 0.97 ✓; at C, 0.97 + 9.03 = 10 ✓; at D, 34.03 = 25 + 9.03 ✓.
Answer: AB = 20.97 lps, BC = 0.97 lps, AD = 34.03 lps, CD = 9.03 lps (from D to C).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Head loss and velocity in loop pipes AB, BC, AC, CD · Water Supply Engineering, chapter 7
- Velocity, head loss, discharge in pipes BC, CD, BF, FD (0.1 m) · Water Supply Engineering, chapter 7
- Design pipes AB, BC, AD (min pressure 1.1 kg/cm2) · Water Supply Engineering, chapter 7 · asked 2×
- Velocity, head loss, discharge in loop pipes BC, CD, BF, FD · Water Supply Engineering, chapter 7
- Design pipes AB, BC and AC, C = 110 · Water Supply Engineering, chapter 7
- Design pipes AB and BC, 20,000 population, f = 0.04 · Water Supply Engineering, chapter 7
- Verify suggested discharge distribution (Hardy Cross) · Hydraulics, chapter 3
- Hardy Cross correction derivation and network · Hydraulics, chapter 3
- Hardy Cross network with valve on diagonal · Hydraulics, chapter 3
- Flow distribution in five-pipe network · Hydraulics, chapter 3