Old tank 11 m x 5 m x 3 m as settling tank

Short answer

Required overflow rate is 0.0600 cm/s (51.9 m³/m²/day). The tank provides 100% removal of 0.05 mm particles, which easily meets the 99% target.

An old tank having dimension of 11 m x 5 m x 3 m is available in a village. It is proposed to use as a settling tank. At least 93 percent of particles having diameter of 0.025 mm, specific gravity 2.65 is expected to remove on the tank at 20°C. What will be an overflow rate on using that tank? Does the tank dimension is enough to remove 99 percentages of particles having diameter 0.05 mm at same conditions?

In an ideal settling tank, particles with vs≥v0v_s\ge v_0 are fully removed, and those with vs<v0v_s<v_0 are removed in the ratio vs/v0v_s/v_0, where v0=Q/Av_0=Q/A is the overflow rate.

Step 1: Settling velocity of the 0.025 mm particles

d=0.0025d=0.0025 cm, Ss=2.65S_s=2.65, ν20=0.01007\nu_{20}=0.01007 cm²/s.

vs=981×1.65×0.0025218×0.01007=0.0558 cm/s(Re=0.014<1)v_s=\frac{981\times1.65\times0.0025^2}{18\times0.01007}=0.0558\ \text{cm/s}\quad(Re=0.014<1)

Step 2: Overflow rate

For 93 % removal:

v0=vs0.93=0.05580.93=0.0600 cm/s=51.9 m3/m2/day (=2.16 m3/m2/h)v_0=\frac{v_s}{0.93}=\frac{0.0558}{0.93}=0.0600\ \text{cm/s}=51.9\ \text{m}^3/\text{m}^2/\text{day}\ (=2.16\ \text{m}^3/\text{m}^2/\text{h})

Surface area A=11×5=55A=11\times5=55 m², so the tank can treat

Q=v0A=0.000600×55=0.03301 m3/s=2852 m3/dayQ=v_0A=0.000600\times55=0.03301\ \text{m}^3/\text{s}=2852\ \text{m}^3/\text{day}

Horizontal velocity =Q/(B H)=0.03301/(5×3)=0.2200=Q/(B\,H)=0.03301/(5\times3)=0.2200 cm/s =0.132=0.132 m/min.

Step 3: Check for 99 % removal of 0.05 mm particles

d=0.005d=0.005 cm:

vs=981×1.65×0.005218×0.01007=0.2232 cm/s(Re=0.111<1)v_s=\frac{981\times1.65\times0.005^2}{18\times0.01007}=0.2232\ \text{cm/s}\quad(Re=0.111<1)

vs=0.2232v_s=0.2232 cm/s is greater than v0=0.0600v_0=0.0600 cm/s (vs/v0=3.72v_s/v_0=3.72), so these particles are removed 100 %, which exceeds 99 %.

Answer: overflow rate = 0.0600 cm/s (51.9 m³/m²/day); yes, the tank is sufficient to remove 99 % of 0.05 mm particles (it removes 100 %).