Intermediate beam for 15 m x 6 m hall

Short answer

Use ISMB 300 (46 kg/m). Factored moment 151.6 kN·m, capacity 152.4 kN·m; shear 303 kN > 97 kN; deflection 13.3 mm < L/300 (20.8 mm). The 110 mm RC slab provides full lateral restraint to the compression flange.

A hall measuring 15 m × 6 m consists of beams spaced at 3 m c/c. R.C.C. slab of 110 mm is cast over the beam. The imposed load is 4 kN/m². The beam is supported on 250 mm wall. Design intermediate beam and check for shear, deflection and lateral stability.

Data

  • Steel Fe 410 (E250): fy=250f_y = 250 N/mm², fu=410f_u = 410 N/mm², E=2×105E = 2\times10^5 N/mm², γm0=1.10\gamma_{m0} = 1.10 (IS 800:2007, Table 5). Limit state design.
  • Effective span L=6.25L = 6.25 m, bearing length of support =250= 250 mm.

Loads and design forces

The hall is 6 m wide, so the beams span 6 m at 3 m c/c. Wall bearing 250 mm: effective span L=6.0+0.25=6.25L = 6.0 + 0.25 = 6.25 m. RCC unit weight 25 kN/m³ (assumed).

  • Slab: 0.11×25=2.750.11\times25 = 2.75 kN/m², on 3 m width =8.25= 8.25 kN/m
  • Imposed: 4×3=12.004\times3 = 12.00 kN/m

wu=1.5(8.25+12.00)=30.375w_u = 1.5(8.25 + 12.00) = 30.375 kN/m plus self-weight. Stiff bearing b1=250b_1 = 250 mm.

Moment without self-weight M=148.3M = 148.3 kN·m, so Zp,req≈Mγm0/fy=148.3×106×1.1/250=653Z_{p,req} \approx M\gamma_{m0}/f_y = 148.3\times10^6\times1.1/250 = 653 cm³ (self-weight adds a little).

Trial section

Try ISMB 300 (IS 808): D=300D = 300 mm, bf=140b_f = 140 mm, tw=7.7t_w = 7.7 mm, tf=13.1t_f = 13.1 mm, R1=14R_1 = 14 mm; Izz=8990I_{zz} = 8990 cm⁴; Ze=599Z_e = 599 cm³; Zp≈Btf(D−tf)+tw(D−2tf)2/4=670Z_p \approx B t_f (D - t_f) + t_w (D - 2t_f)^2/4 = 670 cm³; mass 46.046.0 kg/m.

Self-weight =46.0×9.81/1000=0.451= 46.0\times9.81/1000 = 0.451 kN/m, factored =1.5×0.451=0.677= 1.5\times0.451 = 0.677 kN/m. Total factored UDL w=30.38+0.68=31.05w = 30.38 + 0.68 = 31.05 kN/m.

Mu=wL28=31.05×6.2528=151.6 kN⋅mVu=wL2=97.0 kN\begin{aligned} M_u &= \frac{wL^2}{8} = \frac{31.05\times6.25^2}{8} = 151.6\ \text{kN·m} \\ V_u &= \frac{wL}{2} = 97.0\ \text{kN} \end{aligned}

Section classification (Table 2)

ε=250/fy=1.00\varepsilon = \sqrt{250/f_y} = 1.00. Flange: b/tf=(140/2)/13.1=5.34<9.4ε=9.4b/t_f = (140/2)/13.1 = 5.34 < 9.4\varepsilon = 9.4. Web: d/tw=31.9<84ε=84d/t_w = 31.9 < 84\varepsilon = 84 (with d=D−2(tf+R1)=245.8d = D - 2(t_f + R_1) = 245.8 mm). The section is plastic, so βb=1.0\beta_b = 1.0.

Moment capacity (cl. 8.2.1.2)

The slab, cast over the beam, supports the compression flange throughout its length, so lateral buckling cannot occur; this satisfies the check for lateral stability (cl. 8.2.2).

Md=βbZpfyγm0=670×103×2501.1×106=152.4 kN⋅m1.2Zefy/γm0=1.2×599×103×250/(1.1×106)=163.4 kN⋅m\begin{aligned} M_d &= \frac{\beta_b Z_p f_y}{\gamma_{m0}} = \frac{670\times10^3\times250}{1.1\times10^6} = 152.4\ \text{kN·m} \\ 1.2 Z_e f_y/\gamma_{m0} &= 1.2\times599\times10^3\times250/(1.1\times10^6) = 163.4\ \text{kN·m} \end{aligned}

The smaller value governs: Md=152.4M_d = 152.4 kN·m.

Md=152.4 kN⋅m>Mu=151.6 kN⋅mSafeM_d = 152.4\ \text{kN·m} > M_u = 151.6\ \text{kN·m}\quad \text{Safe}

Shear capacity (cl. 8.4)

Av=Dtw=300×7.7=2310 mm2Vd=Avfy3 γm0=2310×2503×1.1×103=303.1 kN\begin{aligned} A_v &= D t_w = 300\times7.7 = 2310\ \text{mm}^2 \\ V_d &= \frac{A_v f_y}{\sqrt3\,\gamma_{m0}} = \frac{2310\times250}{\sqrt3\times1.1\times10^3} = 303.1\ \text{kN} \end{aligned}

Vu=97.0V_u = 97.0 kN <Vd< V_d; also Vu<0.6Vd=181.9V_u < 0.6V_d = 181.9 kN, so the shear is low and the moment capacity is not reduced (cl. 9.2.1). Web shear buckling does not govern since d/tw=31.9<67ε=67d/t_w = 31.9 < 67\varepsilon = 67 (cl. 8.4.2.1).

Deflection (Table 6)

Deflection under unfactored service (imposed) loads, limit span/300 (floor and roof members, Table 6):

δ=5wL4384EI=5×12.00×(6250)4384×2×105×8990×104=13.26 mm\delta = \frac{5 w L^4}{384 E I} = \frac{5\times12.00\times(6250)^4}{384\times2\times10^5\times8990\times10^4} = 13.26\ \text{mm}

δ=13.26\delta = 13.26 mm <L/300=20.83< L/300 = 20.83 mm. OK.

Web buckling and bearing at support (cl. 8.7.3 and 8.7.4)

Stiff bearing length b1=250b_1 = 250 mm. Clear web depth d=245.8d = 245.8 mm; dispersion of load at 45° to mid-depth at an end support n1=d/2=122.9n_1 = d/2 = 122.9 mm. Effective length 0.7d0.7d (cl. 8.7.1.5), λ=0.7d/(tw/12)=77.4\lambda = 0.7d/(t_w/\sqrt{12}) = 77.4; curve c gives fcd=140.4f_{cd} = 140.4 N/mm².

Fcdw=(b1+n1)twfcd=(250+122.9)×7.7×140.4/103=403.1 kNn2=2.5(tf+R1)=67.8 mmFw=(b1+n2)twfyγm0=(250+67.8)×7.7×2501.1×103=556.1 kN\begin{aligned} F_{cdw} &= (b_1 + n_1) t_w f_{cd} = (250 + 122.9)\times7.7\times140.4/10^3 = 403.1\ \text{kN} \\ n_2 &= 2.5(t_f + R_1) = 67.8\ \text{mm} \\ F_w &= \frac{(b_1 + n_2) t_w f_y}{\gamma_{m0}} = \frac{(250 + 67.8)\times7.7\times250}{1.1\times10^3} = 556.1\ \text{kN} \end{aligned}

Support reaction R=97.0R = 97.0 kN <Fcdw< F_{cdw} and <Fw< F_w. No web stiffener is needed.

Final design

Provide ISMB 300 (46.0 kg/m): Md=152.4M_d = 152.4 kN·m >Mu=151.6> M_u = 151.6 kN·m, Vd=303V_d = 303 kN >Vu=97.0> V_u = 97.0 kN, δ=13.3\delta = 13.3 mm <20.8< 20.8 mm.