Surge tank functions and design criteria
Short answer
A surge tank is an open shaft at the tunnel-penstock junction that provides a free surface to absorb pressure surges. Its main functions are reducing water hammer, handling load changes, and improving governing. Design criteria include upsurge/downsurge levels, Thoma stability area with safety factor 1.5–1.8, and oscillation period avoiding resonance.
Explain about surge tank, its functions and design criteria with necessary sketch.
A surge tank is an open vertical shaft or chamber connected to the pressure conduit (headrace tunnel) at its junction with the penstock, as near the powerhouse as possible. It provides a free water surface that absorbs pressure surges caused by sudden load changes.
reservoir surge tank
~~~~~~~~~ | ^ | max upsurge
| | : |
| static WL -----|--:---|-------
| | v | min downsurge
| headrace tunnel (L, A)|
|========================+
\ penstock
\
\==> turbine
Functions
- Reduces water hammer pressure: the water hammer wave is reflected at the tank, so only the short penstock below it is designed for high water hammer; the long tunnel is protected.
- Load rejection: when turbine gates close, the moving water in the tunnel rises into the tank instead of building up pressure.
- Load acceptance: when gates open, the tank supplies water immediately until the tunnel flow accelerates, preventing a large pressure drop.
- Improves governing of the turbine (better speed regulation).
- Acts as a small reservoir and allows the tunnel to be lighter and cheaper.
Types
Simple (cylindrical), restricted orifice (throttled), differential (Johnson), one-sided/gallery or chamber type, inclined, and air-cushion surge chambers.
Design criteria
- Location: as close as possible to the powerhouse, on sound rock, to reduce penstock length.
- Maximum upsurge on full load rejection (frictionless estimate):
where V = tunnel velocity, L = tunnel length, A = tunnel area, = tank area. The top of the tank must be above static level + upsurge + freeboard (or an overflow is provided).
- Minimum downsurge on load acceptance: the bottom of the tank and the tunnel crown must remain below the lowest water level so that air does not enter the penstock.
- Stability (Thoma criterion): to damp oscillations, area must exceed
( = net head, = tunnel head loss); a factor of safety of 1.5–1.8 is used.
- Period of oscillation: , should not resonate with the governor.
- Structural and economic: shaft lining for rock conditions; choose the type (orifice, differential) to reduce size and cost.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Forebay function and surge tank types · Hydro Power, chapter 5
- Surge tank objectives and economic penstock diameter factors · Hydro Power, chapter 5
- Forebay and surge tank comparison · Hydro Power, chapter 5 · asked 2×
- Desander and its design criteria · Hydro Power, chapter 5 · asked 4×
- Settling basin design principle and components · Hydro Power, chapter 5
- Functions of a surge tank · Hydraulics, chapter 4 · asked 2×
- Surge tank functions and formulas · Hydropower Engineering, chapter 6
- Hydraulic design of surge tank and pressure tunnel · Hydropower Engineering, chapter 6
- Undersluice functions and design criteria · Irrigation and Drainage Engineering, chapter 5 · asked 2×