- 2080 Bhadra · 3+3 marks
Hydraulic design of surge tank and pressure tunnel
Short answer
Surge tank design considers location near powerhouse, type (simple, restricted, differential), cross-section larger than Thoma area, maximum upsurge/downsurge limits, oscillation period, and connection with overflow/air vents. Pressurized tunnel design includes economic diameter with velocity 2.5-4 m/s, friction and local losses, internal pressure including water hammer, adequate rock cover to prevent rupture, HGL above crown, concrete/steel lining, and grouting.
Briefly discuss the hydraulic design considerations of the surge tank and pressurised hydraulic tunnel.
Hydraulic design considerations of the surge tank
- Location: as close to the powerhouse as possible, on stable ground at a level high enough that the maximum surge level stays below the tank top, and the minimum level stays above the tunnel crown.
- Type: simple, restricted orifice, differential (Johnson), or with an upper/lower chamber, chosen by the head, topography and the required reduction of the surge.
- Size: the cross-section must be larger than the Thoma area for stability under small load changes:
- Surge levels: maximum upsurge on full load rejection must not overflow, and minimum downsurge on full-load demand must not expose the tunnel crown (air entry) or the tank bottom; the oscillation period should be checked with the governor.
- Connection: the area of the connecting orifice and the shaft should be sized to give small head loss, but enough damping.
- Provide an overflow, air vents, and access.
Hydraulic design considerations of a pressurised tunnel
- Diameter and velocity: from the economic diameter; velocity usually 2.5-4 m/s.
- Friction and other losses: Manning/Darcy, with of lining; plus entry, bend and transition losses.
- Internal pressure: the maximum internal pressure includes the static head and the surge/water-hammer rise.
- Minimum rock cover: the cover should resist the internal pressure (about ); otherwise the section is steel-lined.
- Hydraulic grade line should stay above the crown at all times, in the transient too, so as to avoid vacuum/negative pressure.
- Lining and grouting: concrete lining for smoothness, steel lining where the rock is weak or the cover is low; contact and consolidation grouting; drainage.
- Protection: air vents and an emergency gate at the intake, and a surge tank at the downstream end to reduce the water hammer in the tunnel.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Surge numerical: 13 m tank, 1.8 km tunnel · Hydropower Engineering, chapter 6
- Surge tank: tunnel 5 m dia, 28 cumec · Hydropower Engineering, chapter 6
- Surge tank: 7.5 m³/s through 2.5 m tunnel · Hydropower Engineering, chapter 6
- Hydraulic design of tunnel; alignment criteria · Hydropower Engineering, chapter 6
- Surge and water hammer: 25 m³/s, 15 m surge tank · Hydropower Engineering, chapter 6 · asked 3×
- Surge and water hammer: 45 m³/s, 20 m surge tank · Hydropower Engineering, chapter 6 · asked 2×
- Time to discharge pressurised tank · Fluid Mechanics, chapter 6
- Surge tank functions and design criteria · Hydro Power, chapter 5 · asked 2×
- Three reservoirs with pressurised closed tank · Hydraulics, chapter 3
- Structural components and the surge tank · Power Plant Design, chapter 3