- 2071 Bhadra · 12 marks
Diversion weir: Bligh and Khosla, 4000 m3/s
Short answer
Bligh creep length 36 m. Khosla design: floor length between piles 12 m, upstream cutoff 3.8 m, downstream cutoff 8.3 m; provided floor thickness 1.0 m (upstream) and 1.5 m (downstream).
A diversion weir with a vertical drop to be designed for an irrigation system has the following data: Design flood = 4000 m³/s; Natural width of the source river = 300 m; Bed material = Coarse sand, Bligh's C = 12; Lacey's f = 1.2; Height of weir above low water = 3.0 m; Top width of the crest = 2.0 m. Fix the length of the floor according to Bligh's principle and design the length of floor and depth of cutoffs using Khosla's seepage theory. Compute the thickness of the floor at key points. Make suitable assumptions if necessary. Draw a neat sketch of the designed weir.
Data and assumptions
m³/s, river width m, Bligh's , Lacey's , weir height above low water m, crest width m. Assumed: river bed (low water) level m, broad-crested weir with (), afflux m, specific gravity of concrete .
1. Waterway and flood levels
Crest level m. Discharge per metre m³/s/m.
2. Scour depth and cutoffs
- U/s pile bottom m, so m; adopt 3.8 m.
- D/s pile bottom m, so m; adopt 8.3 m.
3. Floor length by Bligh's principle
Static head m. Creep length m.
4. Khosla's check and design
Adopt a floor length m between the piles: the 2 m wide crest body occupies the first 2 m, and the d/s floor below the vertical drop the remaining 10 m. Pile depths 3.8 m (u/s) and 8.3 m (d/s); floor thickness 1.0 m (u/s, under the crest) and 1.5 m (d/s) provisionally.
Khosla's constants
, , , (in percent), total floor length m.
| Pile | d (m) | α | λ | φE (%) | φD (%) |
|---|---|---|---|---|---|
| U/s pile | 3.80 | 3.158 | 2.156 | 47.69 | 31.98 |
| D/s pile | 8.30 | 1.446 | 1.379 | 64.87 | 41.14 |
Pressures at the key points
Pressure is expressed as a percentage of the head m (no flow, pond at crest, d/s dry).
Mutual interference ( m):
- at (due to the d/s pile):
- at (due to the u/s pile):
Floor thickness: at , ; at , .
| Point | Simple φ (%) | Corrections (%) | Corrected φ (%) | Pressure head (m) |
|---|---|---|---|---|
| E1 (top of u/s pile) | 100.00 | 0 | 100.00 | 3.00 |
| D1 | 68.02 | - | 68.02 | 2.04 |
| C1 | 52.31 | int +15.93, thk +4.13 | 72.37 | 2.17 |
| E2 | 64.87 | int -10.78, thk -4.29 | 49.80 | 1.49 |
| D2 | 41.14 | - | 41.14 | 1.23 |
| C2 (d/s end) | 0 | 0 | 0 | 0 |
Corrections: int = mutual interference of piles, thk = floor thickness (no slope correction, since the floor is horizontal).
Floor thickness
Unbalanced head = hydraulic-gradient level floor top level; required thickness with . The HGL is taken as a straight line between the corrected values at () and ( m).
| Location | x (m) | φ (%) | HG level (m) | Unbalanced head (m) | Required t (m) | Provided t (m) | Check |
|---|---|---|---|---|---|---|---|
| C1 (under the crest) | 0 | 72.37 | 102.17 | balanced by the weir body and the pond water above | nominal | 1.00 | safe |
| Toe of the drop | 2 | 68.61 | 102.06 | 2.06 | 1.47 | 1.50 | safe |
| E2 (d/s pile) | 12 | 49.80 | 101.49 | 1.49 | 1.07 | 1.50 | safe |
The u/s part of the floor lies under the masonry crest and the pond water, whose weight balances the uplift, so a nominal 1.0 m is enough there. The critical point is just downstream of the vertical drop; provide 1.5 m there. It may be tapered towards the d/s end, but not below about 1.1 m.
Exit gradient
Permissible , so the floor is safe against piping.
Add u/s and d/s aprons (block apron with filter, length - times the scour depth, say about 15 m).
Sketch
HFL u/s ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Crest 103.0 _____ 2.0 m
u/s apron | | vertical drop d/s apron
============ |_____|=========================
100.0 bed |<------ b = 12 m ------>|
pile 3.8 m floor 1.0 m | 1.5 m pile 8.3 m
Answer: Waterway 300 m; crest 103.0 m; u/s cutoff 3.8 m; d/s cutoff 8.3 m; Bligh floor length m, adopted 12 m (Khosla exit gradient 0.098 ); floor thickness 1.0 m (nominal) under the crest and 1.5 m on the d/s floor below the drop.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Weir design by Bligh's theory, 3200 m3/s · Irrigation and Drainage Engineering, chapter 5
- Vertical drop design, Q 1.8 m3/s (bed 205.05) · Irrigation and Drainage Engineering, chapter 7 · asked 4×
- Vertical drop design, Q 7.5 m3/s · Irrigation and Drainage Engineering, chapter 7 · asked 4×
- Vertical drop design, Q 5.2 m3/s · Irrigation and Drainage Engineering, chapter 7 · asked 4×
- Vertical drop design, Q 2.1 m3/s · Irrigation and Drainage Engineering, chapter 7 · asked 4×
- Vertical drop design, Q 1.8 m3/s (drop 0.75 m) · Irrigation and Drainage Engineering, chapter 7 · asked 2×
- Irrigation canal earthwork with vertical drop · Estimating and Costing, chapter 6
- Return period of 350 m3/s design flood by Gumbel · Engineering Hydrology, chapter 6 · asked 2×
- Design: 4000 kVA 66/11 kV power transformer · Electric Machine Design, chapter 3 · asked 5×
- Coarse material thickness against piping · Soil Mechanics, chapter 7
All Irrigation and Drainage Engineering chapter 5 questions →