RMS and fundamental of stepped inverter waveform
Short answer
The six-step wave has 200 V and 400 V steps each 60°. RMS voltage = sqrt[(200^2*2 + 400^2)/3] = 282.84 V. Peak fundamental from Fourier expansion: V1m = (2/π)*600 = 381.97 V.
Figure shows the waveform of output voltage (per phase) of three phase inverter. Calculate RMS value and peak value of fundamental component of the output voltage. [Figure: per-phase output voltage Vo of a three-phase inverter vs ωt — +200 V from 0° to 60°, +400 V from 60° to 120°, +200 V from 120° to 180°, then −200 V from 180° to 240°, −400 V from 240° to 300°, −200 V from 300° to 360°]
The given wave (steps of 200 V and 400 V, each 60° wide) is the per-phase voltage of a 180°-conduction three-phase inverter with V, i.e. V.
RMS value
Each 60° block occupies rad. Using the half cycle (the negative half is a mirror image):
(Check: V.)
Peak value of the fundamental
The wave has half-wave and quarter-wave (odd) symmetry, so and
For : , , :
(Check: V.) RMS of fundamental V.
The same formula gives (no triplen harmonics), V, V.
Answer: V; peak fundamental V (270.09 V rms).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- 180° three-phase inverter and fundamental phase voltage · Power Electronics, chapter 5
- Fundamental and 3rd harmonic of 180° inverter output · Power Electronics, chapter 5
- Fundamental and 3rd harmonic of three-phase inverter output · Power Electronics, chapter 5
- Three-phase bridge inverter 180° and 120° numerical · Power Electronics, chapter 5
- Single-phase square-wave inverter rms and fundamental · Power Electronics, chapter 5
- Single-phase inverter fundamental output voltage · Power Electronics, chapter 5
- Insulator discs per string, 180 MW over 200 km · Transmission and Distribution System Design, chapter 3
- Output voltage Vo using Kirchhoff laws · Basic Electrical Engineering, chapter 2
- Average and RMS of sawtooth waveform · Fundamental of Electrical and Electronics Engineering, chapter 2
- Initial line design for 200 MW over 120 km · Transmission and Distribution System Design, chapter 2