Volt/Hz control and frequency control schemes
Short answer
V/f control keeps air-gap flux constant by varying voltage with frequency. Frequency control schemes include PWM voltage-source inverter, square-wave inverter, current-source inverter, and cycloconverter. Control modes are open-loop V/f, closed-loop slip regulation, and vector control.
Starting from Volt/Hz control of three phase induction motors. Discuss their frequency control schemes.
Volt/Hz control varies the supply frequency of an induction motor to change its synchronous speed, while changing the voltage in proportion so that the air-gap flux stays constant.
Basis of V/f control
- Keeping constant keeps and constant; speed–torque curves shift parallel with frequency.
- At low frequency, a voltage boost compensates the stator drop.
- Above base frequency, voltage is held at rated value: flux and fall (constant power, field-weakening region).
V | _________ V rated
| /
| / V/f const
| /
|/ <- boost V0
+------+----------> f
f base
Frequency control schemes
1. Voltage source inverter (VSI) / PWM inverter drive
ac -> [diode rectifier] -> C -> [PWM inverter] -> IM
- Diode rectifier and capacitor give stiff dc; PWM inverter gives variable and together. Low harmonics, wide range, many motors from one inverter. Regeneration needs an extra converter or braking chopper.
2. Variable-voltage (square-wave) inverter
- Controlled rectifier or chopper varies the dc link voltage; six-step inverter varies frequency. Simple, but harmonics at low speed and poor input power factor.
3. Current source inverter (CSI) drive
- Controlled rectifier with large dc link inductor gives a stiff current; inverter switches it to the phases. Inherent regeneration and short-circuit protection; used for single large motors (fans, pumps). Torque pulsations at low speed.
4. Cycloconverter drive
- Direct ac–ac conversion to a lower frequency (up to about 1/3 of supply). For large, low-speed drives (cement mills, ship propulsion).
Control modes
- Open-loop V/f: frequency set from speed reference, voltage from V/f function; simple, used for fans and pumps; speed drops with load.
- Closed-loop slip regulation: speed is sensed; PI controller sets slip frequency, ; slip limit gives current/torque limit and good regulation.
- Constant flux / vector control: stator current controlled so that flux and torque components are regulated separately, giving dc-motor-like dynamic performance.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Variable frequency control of induction motor · Utilization of Electrical Energy, chapter 3
- Starting induction motor with variable frequency · Utilization of Electrical Energy, chapter 3
- Low frequency induction furnace with half-full hearth · Utilization of Electrical Energy, chapter 5 · asked 2×
- Constant V/f control of induction motor · Utilization of Electrical Energy, chapter 3 · asked 2×
- Capacitor bank for 340 kW induction motor · Utilization of Electrical Energy, chapter 6 · asked 2×
- Induction motor plugging: braking current and torque · Utilization of Electrical Energy, chapter 3
- Output equation of three phase induction motor · Electric Machine Design, chapter 4 · asked 6×
- 1-phase IM not self-starting; two methods · Electrical Machine, chapter 7 · asked 2×
- Why single-phase IM is not self starting; methods · Electric Machines II, chapter 3 · asked 2×
- Reason: 1-phase IM not self-starting · Electrical Machine, chapter 7