- 2073 Shrawan · 6 marks
1:32 DEMUX tree from 1:8 and 1:2 DEMUXes
Short answer
Build in three levels: one 1:2 DEMUX with S4 feeds two 1:2 DEMUXs with S3, each feeding two 1:8 DEMUXs with S2-S0, producing 32 outputs. No additional gates are required.
Design 1:32 demultiplexer tree using 1:8 DEMUXs and 1:2 DEMUXs only.
A 1:32 DEMUX has one data input , five select lines and 32 outputs –. Since , it can be built with three 1:2 DEMUXes and four 1:8 DEMUXes in three levels.
Design
| Level | DEMUXes | Select | Outputs |
|---|---|---|---|
| 1 | one 1:2 (DM-A) | 2 lines | |
| 2 | two 1:2 (DM-B, DM-C) | 4 lines | |
| 3 | four 1:8 (DM1–DM4) | 32 outputs |
S3 S2 S1 S0
+-------+
+----->| DM-B |------> [1:8 DM1] --> Y0..Y7
| | 1:2 |------> [1:8 DM2] --> Y8..Y15
S4 | +-------+
+-------+ |
D>| DM-A |--+
| 1:2 |-----+
+-------+ | S3
| +-------+
+-->| DM-C |------> [1:8 DM3] --> Y16..Y23
| 1:2 |------> [1:8 DM4] --> Y24..Y31
+-------+
- DM-A output 0 (when ) feeds DM-B; output 1 feeds DM-C.
- DM-B sends data to DM1 () or DM2 (); DM-C to DM3 or DM4.
- Each 1:8 DEMUX decodes to one of its eight outputs.
| Active 1:8 DEMUX | Output range | |
|---|---|---|
| 00 | DM1 | – |
| 01 | DM2 | – |
| 10 | DM3 | – |
| 11 | DM4 | – |
Example
(): DM-A () → DM-C; DM-C () → DM4; DM4 () → its output 2, which is . So appears at and all other outputs stay 0.
Total: 3 DEMUXes of 1:2 + 4 DEMUXes of 1:8 = 7 ICs, no extra gates.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- 1:16 DEMUX using 1:2 DEMUXes · Digital Logic, chapter 4
- Multiplexer tree; 1:16 DEMUX from 1:4 · Digital Logic, chapter 4
- 32:1 MUX tree from 4:1; implement Σ(0,1,3,8,9,13) · Digital Logic, chapter 4
- 32:1 MUX tree; implement Σm(0,1,3,8,9,13,15) · Digital Logic, chapter 4
- Full subtractor using a 1:4 DEMUX · Digital Logic, chapter 4 · asked 6×
- Full adder using a single 1:4 DEMUX · Digital Logic, chapter 4 · asked 5×
- AVL tree for 52, 65, 72, 15, 11, 32, 20 · Data Structure and Algorithm, chapter 6
- Why design for active pressure only · Foundation Engineering, chapter 3 · asked 4×
- T/F: tower height function of voltage only · Transmission and Distribution System Design, chapter 4 · asked 2×
- Siphon aqueduct: Q 50, bed 32 m · Irrigation and Drainage Engineering, chapter 8 · asked 2×