Assuming iron loss 100 W, full-load copper loss is scaled from SC test: 200×(12.5/11.4)^2 = 240.5 W. Output 4500 W at 0.9 pf. Efficiency = 92.97%. Voltage regulation using R02=1.539 Ω, X02=3.153 Ω and 0.9 pf lagging = 8.62%.

Open circuit and Short circuit test on 5 kVA, 220/400 V, 50 Hz, single phase transformer gave the following results. Short circuit test (on H.V. side): 40 V, 11.4 A, 200 watts. Determine the efficiency and the voltage regulation of the transformer at full load at 0.9 pf lagging.

Only the short-circuit data is given; the open-circuit result is needed for iron loss. Assumption: the usual OC data for this textbook problem, 220 V, 2 A, 100 W on the LV side, i.e. iron loss Pi=100P_i = 100 W. (If a different OC wattmeter reading is given, replace 100 W.)

Rated HV current: I2=5000400=12.5I_2 = \frac{5000}{400} = 12.5 A. The SC test was done at 11.4 A, so its copper loss must be scaled to full load.

Parameters from SC test (HV side)

Z02=4011.4=3.509 ΩR02=20011.42=1.539 ΩX02=3.5092−1.5392=3.153 Ω\begin{aligned} Z_{02} &= \frac{40}{11.4} = 3.509\ \Omega \\ R_{02} &= \frac{200}{11.4^2} = 1.539\ \Omega \\ X_{02} &= \sqrt{3.509^2 - 1.539^2} = 3.153\ \Omega \end{aligned}

Full-load copper loss

Pcu,FL=200×(12.511.4)2=I22R02=12.52×1.539=240.5 WP_{cu,FL} = 200 \times \left(\frac{12.5}{11.4}\right)^2 = I_2^2R_{02} = 12.5^2 \times 1.539 = 240.5\ \text{W}

Efficiency at full load, 0.9 pf lagging

Output=5000×0.9=4500 WLosses=Pi+Pcu=100+240.5=340.5 Wη=45004500+340.5×100=92.97%\begin{aligned} \text{Output} &= 5000 \times 0.9 = 4500\ \text{W} \\ \text{Losses} &= P_i + P_{cu} = 100 + 240.5 = 340.5\ \text{W} \\ \eta &= \frac{4500}{4500 + 340.5} \times 100 = 92.97\% \end{aligned}

Voltage regulation at full load, 0.9 pf lagging

cos⁡ϕ=0.9\cos\phi = 0.9, sin⁡ϕ=0.4359\sin\phi = 0.4359.

%Reg=I2(R02cos⁡ϕ+X02sin⁡ϕ)V2×100=12.5 (1.539×0.9+3.153×0.4359)400×100=12.5×(1.385+1.375)400×100=8.62%\begin{aligned} \%\text{Reg} &= \frac{I_2(R_{02}\cos\phi + X_{02}\sin\phi)}{V_2}\times 100 \\ &= \frac{12.5\,(1.539 \times 0.9 + 3.153 \times 0.4359)}{400}\times 100 \\ &= \frac{12.5 \times (1.385 + 1.375)}{400}\times 100 = 8.62\% \end{aligned}

The regulation does not depend on the OC test, so 8.62% holds whatever the iron loss is.

Answer: Full-load efficiency at 0.9 pf lagging ≈\approx 92.97% (with PiP_i = 100 W); voltage regulation = 8.62%.