20 kVA 250/2500 V tests, regulation, efficiency

Short answer

From OC test: R0=595.2 Ω, X0=187.2 Ω. From SC test referred to primary: R01=0.05 Ω, X01=0.1414 Ω. Voltage regulation at half load, 0.8 pf lag: VR=2.0%. Efficiency at half load: 97.74%.

A 20 kVA, 250 V/2500 V, 50 Hz single phase transformer gave the following test result: Open circuit test: 250 V, 1.4 A, 105 watts Short circuit test: 120 V, 8 A, 320 watts Calculate the equivalent circuit parameters referred to primary side and draw the equivalent circuit. Also calculate voltage regulation and efficiency at half full load for an 0.8 p.f. lagging.

Given: 20 kVA, 250 V/2500 V. Primary = LV (250 V), K=2500/250=10K = 2500/250 = 10, K2=100K^2 = 100.

Equivalent circuit parameters (referred to primary)

OC test (LV side): 250 V, 1.4 A, 105 W

cos⁡ϕ0=105250×1.4=0.3,Iw=0.42 A,Iμ=1.42−0.422=1.3355 AR0=2500.42=595.2 Ω,X0=2501.3355=187.2 Ω\begin{aligned} \cos\phi_0 &= \frac{105}{250\times1.4} = 0.3,\quad I_w = 0.42\ \text{A},\quad I_\mu = \sqrt{1.4^2 - 0.42^2} = 1.3355\ \text{A} \\ R_0 &= \frac{250}{0.42} = 595.2\ \Omega,\qquad X_0 = \frac{250}{1.3355} = 187.2\ \Omega \end{aligned}

SC test (HV side): 120 V, 8 A, 320 W. (The rated HV current is 20 000/2500=820\,000/2500 = 8 A, so this is a full-load test.)

Zeq,H=1208=15 Ω,Req,H=32082=5 Ω,Xeq,H=152−52=14.14 Ω\begin{aligned} Z_{eq,H} &= \frac{120}{8} = 15\ \Omega,\quad R_{eq,H} = \frac{320}{8^2} = 5\ \Omega,\quad X_{eq,H} = \sqrt{15^2 - 5^2} = 14.14\ \Omega \end{aligned}

Referred to primary (LV) by dividing by K2=100K^2 = 100:

R01=0.05 Ω,X01=0.1414 Ω,Z01=0.15 ΩR_{01} = 0.05\ \Omega,\qquad X_{01} = 0.1414\ \Omega,\qquad Z_{01} = 0.15\ \Omega
   R01=0.05 ohm   X01=0.1414 ohm
 o--+-----/\/\/\-----UUUU------o
    |
   [R0=595.2] [X0=187.2]   Load
    |
 o--+---------------------------o

Voltage regulation at half load, 0.8 pf lagging

Rated primary current I1=20 000/250=80I_1 = 20\,000/250 = 80 A; half load gives I1=40I_1 = 40 A.

I1(R01cos⁡ϕ+X01sin⁡ϕ)=40(0.05×0.8+0.1414×0.6)=4.994 VVR=4.994250×100=2.0%\begin{aligned} I_1(R_{01}\cos\phi + X_{01}\sin\phi) &= 40(0.05\times0.8 + 0.1414\times0.6) = 4.994\ \text{V} \\ \text{VR} &= \frac{4.994}{250}\times100 = 2.0\% \end{aligned}

Efficiency at half load, 0.8 pf lagging

Pout=0.5×20 000×0.8=8000 WPcu=0.52×320=80 W,Pi=105 Wη=80008000+80+105×100=97.74%\begin{aligned} P_{out} &= 0.5\times20\,000\times0.8 = 8000\ \text{W} \\ P_{cu} &= 0.5^2\times320 = 80\ \text{W},\qquad P_i = 105\ \text{W} \\ \eta &= \frac{8000}{8000 + 80 + 105}\times100 = 97.74\% \end{aligned}

Answer: R01=0.05 ΩR_{01} = 0.05\ \Omega, X01=0.1414 ΩX_{01} = 0.1414\ \Omega, R0=595.2 ΩR_0 = 595.2\ \Omega, X0=187.2 ΩX_0 = 187.2\ \Omega; regulation ≈2.0%\approx 2.0\%; efficiency =97.74%= 97.74\%